background image

9. FITTING THE MIXER VALVE  

EXPOSED OPTION

IMPORTANT: Ensure that you have read through section 7. IMPORTANT INSTALLATION INFORMATION before 

starting to fit the mixer valve.

1.  Your thermostatic concentric mixer valve is set up 

in the factory so that a shower hose can be fitted. 

This means that when the valve is fitted with the hot 

water coming in from the left hand side, indicated 

by the red spot, the water outlet is on the bottom of 

the valve and has a ½” BSP threaded male outlet 

(Fig 1).

2.  The supply pipework can be plumbed from above 

or below but must finish at the suitable connections 

which should be at 155mm centers. Connect the 

15mm pipework using standard compression nut 

and olives supplied with the mixer valve (Fig 2).

NOTE: Make sure the mixer valve is kept in a clean 

place to prevent rubbish etc, getting into the openings 

while fitting the pipework. 

3.  Complete the fitting of the pipework and the tiling 

leaving the pipework as shown.Leave 155mm  

(+ or - 5mm) between centers and about 30mm  

out from the finished surface (Fig 3).

4.  Remove the back plate from the mixer valve by 

removing the retaining grub screws. Put the plate 

in the centre between the feed pipes and mark the 

screw positions, check this fits by holding the valve 

in position. Drill plug and screw the back plate to 

the wall (Fig 4). 

5.   Fit the two flat valve nut covers to the nuts on the 

mixer valve and position the mixer valve onto the 

two water feed pipes and onto the wall bracket. 

To prevent moisture entering the wall put some 

silicone on the underside of the mixer valve nut 

covers.Carefully tighten up  the compression nuts 

to hold the mixer valve in place (Fig 5).

6.  Make sure the mixer valve outlet is pointing in the 

correct direction (with the hot feed on the left side 

marked with a red indicator). Replace the locking 

grub screws to hold the mixer valve onto the wall 

plate.

CAUTION

Check there are no hidden cables or pipes before drilling holes for wall plugs.  

Exercise great care when using power tools near water.  

The use of a residual current device (RCD) is recommended.

!

!

!

!

155mm approx

5

4

3

1

2

Hot Water

 

1/2” Male

Содержание Atmos Fusion

Страница 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Fusion Thermostatic Concentric Mixer Valve with Riser Rail ...

Страница 2: ...suresystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTANT Beforeinstallingwithagas instantaneouswaterheater makesureitiscapable ofdeliveringhotwaterataminimumswitch onflow rateof3litresperminute Atflowratesbetween3and8litresperminute theappliancemustbeca...

Страница 3: ...utCovers 2 FilterWashers 2 HoseRetainingRing 1 10mmAllenKey 1 PressureBalanceKit 1 ScrewPack 2screws 2plugs 1 FittingInstructions 1 TMVRegistrationCard 1 Allen Key Pressure Balance Kit Screw Pack Fitting Instructions and TMV Registration Card Nut Covers Hose Retaining Ring Filter Washers Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation 6 ModeHandset 1 5m...

Страница 4: ...ndent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures stated in this guide Always test the water temperature with your hand before entering the shower NOTE As a competent person installing this shower you should ensure that all users are very conversant...

Страница 5: ...Bar Thisshouldbeconfirmedbytheinstallation engineerorcompetentperson beforeinstallation WATER TEMPERATURE REQUIREMENTS Maximumhotwatertemperature 80 C Recommendedmaximum 65 C Minimumhotwatertemperature 55 C Maximumcoldwatertemperature 20 C TEMPERATURE ADJUSTMENT RANGE Themixedwatertemperaturecanbeadjustedfrom coldthroughtohot Thereisasafetystoppresetata settemperatureofabout38 C Alwaystestthewater...

Страница 6: ...ointdown ifthemixervalveisforan overheadtheoutletshouldpointupwards n Themixervalveisdesignedtoworkatthesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto thehigherpressuresupplytothevalve Thisisbest donebytestingeachonetofindoutwhichgivesthe bestresults n Themixervalvewillbeinstalledinsuchaposition thatthemaintenanceoftheTMVanditsvalvesand thecommiss...

Страница 7: ...peworkasshown Leave155mm or 5mm betweencentersandabout30mm outfromthefinishedsurface Fig3 4 Removethebackplatefromthemixervalveby removingtheretaininggrubscrews Puttheplate inthecentrebetweenthefeedpipesandmarkthe screwpositions checkthisfitsbyholdingthevalve inposition Drillplugandscrewthebackplateto thewall Fig4 5 Fitthetwoflatvalvenutcoverstothenutsonthe mixervalveandpositionthemixervalveontoth...

Страница 8: ...ositions checkthisfits byholdingthemixervalveinposition Drillplugand screwthebackplatetothewall Fig2 4 Positionthemixervalveontothetwowaterfeed pipesandontothewallbracket Tightenupthe compressionnutstoholdthemixervalveinplace Fig3 NOTE Makesurethemixervalveoutletispointing downandthehotfeedisontotheleftsidemarked witharedindicator 5 Replacelockingscrewstoholdthemixervalveonto thewallplate Fig4 6 A...

Страница 9: ...omoftherailassembly Fig3 NOTE Thesoapdishinthiskitissupplied withfittingstofitbothovalandroundrailsitis assembledwitharubberinsertfortheovalrail andmustbechangedtotheroundonewhichis provided 5 Replacetherailassemblyontothelower bracketrefitthetopbracketensuretheslotor indentintherailislocatedintothebracketnotch andfixtothewall 6 Tofitthehandset connectoneendofthedouble interlockhosetotheoutletonth...

Страница 10: ...lets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly Runthevalveat the38 Cstopposition Checkthewatertemperature 5 Turnoffthefeedofcoldwaterusingtheisolation valve Thewaterflowshouldfalltoaverylowflow possiblyonlyadrip afterafewseconds 6 Collectthewate...

Страница 11: ...vevalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpressure Q WatertooCOLD A Ninethingstocheck 1 Temperaturecontrolisnotcorrectly commissioned Adjustthetemperaturecontrol thisisonlyajob forasuitablyqualifiedperson 2 Notenoughhotwaterflowingthroughshower ...

Страница 12: ...ptoyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe productandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranyproductsthathavebeen modified alteredortransformedinanyway 5 Thisguaranteeappliestoanoriginalinstallationinaccordance toourfittinginstructionsanddoesnotcoverpreviouslyinstalled products showroomdisplay...

Страница 13: ...ngineersvisit Theengineerwillnot beabletorepairorreplaceoradviseonpartsor productsnotsuppliedbyMX 4 Intheeventofaservicecallabortedbyyouor whereacallhasbeenbookedunderourguarantee butfailureisnotrelatedtotheproductsuppliedby MXthenachargewillbemade 5 Iftheproductisnolongercoveredbytheguarantee achargewillbemadeforthesite visitandforany partssupplied 6 Servicechargesarebasedontheaccountbeing settle...

Страница 14: ...NOTES ...

Страница 15: ...NOTES ...

Страница 16: ... sales mx group com www mx group com CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either through non availability of materials or due to our policy of continuing technical improvement Therefore the Company reserves the right to change specification or withdraw products from this list withou...