11. OPERATING THE SHOWER 

1.  Switch on pull-cord or wall mounted switch.
2.  Turn the power selector knob to the cold 

setting 

 for immediate water fl ow.

3.  Select your power setting using the top 

control. The shower has three positions 

COLD 

, ECO 

 and FULL

 power. 

COLD 

 setting (Solid Blue Symbol):

Adjustment of the fl ow control on this setting 

will only alter the fl ow of water not the water 

temperature. 
ECO 

 settings (Open Red Symbol): 

This is the low power setting for economy 

during warmer months or when a cool 

shower is required. Temperature adjustment 

is via the bottom temperature control.
FULL 

 setting (Solid Red Symbol): 

This is the full power setting. Temperature 

adjustment is via the bottom temperature 

control.

4.  Wait a few seconds for the warmer water to 

reach the showerhead.

5.  If necessary turn bottom ‘Temperature’ 

control knob slowly to obtain desired 

showering temperature. Again, waiting 

a few seconds after each adjustment in 

temperature to reach the showerhead.

Note:

To adjust the shower temperature. 

The water temperature is altered by increasing 

or decreasing the fl ow rate of water through the 

shower unit via the temperature control.
To increase the shower temperature.

Turn the temperature control knob clockwise, 

this will decrease the fl ow of water and increase 

the shower temperature.
To decrease the shower temperature. Turn the 

temperature control knob anti-clockwise, this 

will increase the fl ow of water and decrease the 

shower temperature.
6.  To turn off the shower unit, turn the power 

selector knob to the OFF position.

7.  A small amount of water will be retained in 

the showerhead after the shower has been 

turned off. This may drain over a few minutes.

8. Switch of pull-cord or wall mounted switch.

WARNING

IF RE-STARTING THE SHOWER IMMEDIATELY AFTER STOPPING, BE AWARE THAT A SLUG 

OF HOT WATER WILL BE EXPELLED FOR THE FIRST FEW SECONDS.

!

!

!

!

TTeee

TTTTTT m

mpera

rr tuurree

rrrr

COOLER

COOLER

WARMER

WARMER

eco

eco

eco

eco

eco

eco

eco

eco

ON/OFF

COLD

HOT

ECO

12. SHOWERHEAD CLEANING INSTRUCTIONS 

The showerhead should be cleaned periodically to remove limescale or debris which will 

reduce the performance of the shower. The frequency of cleaning will vary according to local 

water quality. 

PERIODICAL MAINTENANCE

1. To break away scale 

deposits on a daily basis 

simply rub your thumb 

over the surface whilst the 

shower is running.

2. If scale deposits 

are stubborn,soak 

the showerhead in a 

proprietary limescale 

remover and rinse 

thoroughly before use.

3. Remove the fi lter from 

the bottom of the shower 

clean out any debris by 

washing in clean water. 

Refi t fi lter.

ATTENTION!

DO NOT OPERATE THE SHOWER UNIT IF THE SHOWERHEAD 

OR HOSE BECOMES DAMAGED.

THE SHOWER IS DESIGNED AND APPROVED TO EN-60335 WITH THE SHOWERHEAD 

PROVIDED. UNDER NO CIRCUMSTANCES MUST ANY SHOWERHEAD THAT IS NOT

APPROVED BY THE MANUFACTURER BE USED WITH THIS PRODUCT.

Содержание Solo QI

Страница 1: ...Instantaneous Electric Shower Installation Instructions IMPORTANT ThisStep by Stepguideshouldbegiventothecustomer afterinstallationanddemonstration ...

Страница 2: ...t risk provided they are installed used and maintained in good working order in accordance with our instructions and recommendations WARNING DO NOT operate shower if frozen or suspected of being frozen It must thaw out before using DO NOT operate the unit if the showerhead or spray hose becomes damaged DO NOT restrict flow out of shower by placing showerhead in direct contact with your body DO NOT...

Страница 3: ... are fully tightened and that no cable insulation is trapped under screws Ensure the cable clamp is used to secure the cable The earth continuity conductor of the electrical installation must be effectively bonded to earth on the fuse board CAUTION Check there are no hidden cables or pipes before drilling holes for wall plugs Exercise great care when using power tools near water The use of a resid...

Страница 4: ...offattheisolatingswitchwhennot inuse 3 GENERALADVICETOSHOWERUNITUSERS Thefollowingpointswillhelpyoutounderstandhow yourMXshowerunitoperates Theflowrateofwaterpassingthroughtheshower unitdeterminesthewatertemperature Thelowerthe flowthewarmerthewater thehighertheflowthe coolerthewater Thetemperatureproducedbytheshowerunitwill varybetweenseasonsonanyonesettingofthe temperaturecontrol Thisisduetovari...

Страница 5: ...ren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 5 INSTALLATION Positionyourshowerunitonthewallawayfromthe directsprayoftheshowerandataboutthesame ...

Страница 6: ...pulloff 3 Simplyrefitblankingcaptotheinletpipeonthe righthandsideoftheunit 4 Re insertthemetalfixingclipensuringitispushed firmlyintothegroove 5 Whenleaktestingtheinstallationyoumustensure therearenoleaksfromthisarea Turnoffthewatersupplyattheisolatingstoptap Havingdeterminedthedirectionoftheinletwater supply Top falling Bottom rising orBackinlets It isnecessarytoremovetheappropriateplasticcross s...

Страница 7: ...8m 9 5 39 58amps 40amps 40amps 21m 32m 10 5 43 75amps 45amps 45amps 18m 30m Nominal Power rating at 240V 7 5kW 32A MCB rating 8 5kW 40A MCB rating 9 5kW 40A MCB rating 10 5kW 45A MCB rating Nominal Power rating at 230V 6 9kW 32A MCB rating 7 8kW 40A MCB rating 8 7kW 40A MCB rating 9 6kW 45A MCB rating L N E Terminal block 1 Terminal block 2 Power neon 3 Right microswitch 4 Left microswitch 4 5 7 6...

Страница 8: ... double pole isolating switch 2 Turn the top power selector knob to the Cold setting Solid Blue Symbol 3 Turn the bottom temperature control knob anti clockwise to the full cold position 4 Ensuring the water supply is fully on at the mains stop cock and isolating service valve if fitted check that water is not leaking from the bottom of the case 5 Switch on the electrical supply at the double pole...

Страница 9: ... the temperature control knob anti clockwise this will increase the flow of water and decrease the shower temperature 6 To turn off the shower unit turn the power selector knob to the OFF position 7 A small amount of water will be retained in the showerhead after the shower has been turned off This may drain over a few minutes 8 Switch of pull cord or wall mounted switch WARNING IF RE STARTING THE...

Страница 10: ...system Oncethishas beencarriedoutyouwillneedtofitanew pressurereliefdevice Contacttheservice lineon 2 Checkmainswaterconnections 3 Cleantheshowerheadofanydirtanddebris andifnecessaryreplacetheshowerhead andhose Oncethishasbeencarriedoutyou willneedtofitanewpressurereliefdevice Contacttheservicelineon Q Thefilterorshowerheadkeepsblockingorfilling upwithsolidmaterials A Aftertheinitialinstallationno...

Страница 11: ...defects Itdoesnotapplytonormalwearandtear accidentaldamage inappropriateuse includinginappropriatecleaning orotherevents outsidethemanufacturer scontrol 7 Thisguaranteeappliesonlytotheproductitselfandasaresultany liabilityattributedtoMXGroupislimitedtothecostofthecomponent 8 IfaproductisdeemedtobeoffaultymanufactureMXGroupwillat theirdiscretionreplacethecomponent Anyrelatedconsequential lossordama...

Страница 12: ...NOTES NOTES ...

Страница 13: ...roup com CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either through non availability of materials or due to our policy of continuing technical improvement Therefore the Company reserves the right to change specification or withdraw products from this list without prior notice being given ...

Отзывы: