TOOLS
4 Area of application
• This cable winch is used to hoist and lower loads.
• The transportation of persons or animals is not permitted.
• Loads can only be hoisted and lowered vertically.
• Other applications are excluded.
• While lifting a load if the raising power is so low that the load can’t be raised, check if the voltage on-site is 230 V. The
machine works efficiently with a voltage of 230 V, if the voltage does not meet the requirements, one must reduce the load.
5 Preparation
Prior to start-up operation, please be sure to make some preparations:
• Make sure the voltage of your power network complies with the voltage listed on the data plate and that the device is
equipped with the correct power plug.
•
Please make no-loading test before start-up operation at first, and please check:
a. The flexibility of up/down operating switch to insure the controlling of the hoisting and lowering of load hook.
b. The flexibility of up limit bracket to make sure the cut-off of circuit.
c. The flexibility of down limit bracket to make sure the cut-off circuit when the steel cable is nearly used up.
d. Any abnormal sounds when start-up operation.
e. The steel rope is possible damaged (split or bent), or reach 20 hours after using, change the rope immediately.
• Please inspect the brake disc before operating at every 20 hours after load, need to check the brake disc. If the load is
downslide or the brake is not flexible, replace the relevant components in time.
• Please inspect the hook before operation is possible damaged or distortional, replace it in time.
• Operation using a residual current protective device (Red Emergency Stop Switch) offers additional protection under danger
and in emergency circumstances, then screw the switch head as the arrow direction to recover operation after remove the
danger.
• Please be sure to the enough lubricant on parts. Daub the lubricant on the load hook, cable drum shaft, slow down box,
and bearing every half a year.
• Please daub the lubricant on the nesting of cable drum shaft when replace the steel cable every time. Immediately replace
the cable if damaged.
• Please perform any rework and maintenance tasks only if the power plug is disconnected.
• Please inspect the device for transportation damages. Immediately report any possible damages to your seller.
6 Installation
1.
Install the cable winch on a steel beam (see fig. 2). Use only the enclosed installation brackets which can be attached
to the top of the mounting casing using the screws, washers and spring lock washers. The steel beam must be able to
withstand at least double the rated weight of the machine. Contact a professional installer for best results.
2. The steel beam must have a diameter of 46 mm, a wall thickness of at least 2.3 mm and a length of at least 450 mm (see
fig. 2, below).
3. The steel beam must be securely anchored in a wall. The anchor must be installed correspondingly sturdy in order to be
able to withstand the load.
4. Please be sure that the machine is installed level and not slanted.
5.
The remote control must be easily accessible at all times and must therefore be installed at a distance to the floor of
between 0.8 m and 1.5 m (see fig. 3, above).
6. Insert the load hook into the hook bracket of the mounting casing when using the additional load hook with deviating shaft.
7. The electric pulley will be attached at the top. Attach the pulley with bearer frame on the crossbar. The girder is then
attached to the support columns. The support columns must be, in accordance with the requirements of the customer,
properly secured on the working area. The support columns must be installed to be sturdy and stable. Also be able to
withstand a nominal load long-term.
8
Technical Specifications
Type
YT-125
/
250-A
YT-300/600
YT-500/999
Rated
voltage
230
v~
230
v~
230
v~
Rated frequency
50
Hz
50
Hz
50
Hz
Power rating:
500W
1050W
1600W
Rated
current
2.18 A
4
.
6A
7.5A
Max. loading
capacity
-for
single
cable
-for double
cable
125 kg
250 kg
300 kg
600 kg
500 kg
999kg
Cable speed
-for
single cable
-For double
cable
8
m/min
4m/min
8
m/min
4m/min
8
m/min
4m/min
Hoisting height
-for
single cable
-For double
cable
12 m
6 m
12 m
6 m
18 m
9 m
Cable diameter
3
,
0
mm
4
,
5
mm
6
,
0
mm
Protection rating
IP54
IP54
IP54
Motor
category
M
1
M
1
M
1
Work duty
S320
%-
10min
S320
%-
10min
S325
%-
10min
Protection rating
I
I
I
Weight
1
1.0
kg
18.0kg
34.0kg
Sound pressure
level (LWA)
71
dB(A)
71
dB(A)
71
dB(A)
•
The LWA
val
ues
stated
here
only
indicate the loudness emitted
by
this machine
.
Whether
the
operator
is
required to
wear
hearing protection
can’
t
be
determined here
.
This depends
on
how much noise
reaches
the
ear of
the
operator
.
And
this
,
among other
things
,
depends on
the existing
ambient
conditions (such as other sources of
noise nearby)
.
Even though it may not be
explicitly
required
,
it is
in your own interest
to
always wear
hearing
protection when operating
this machine
.
YT-125/250-A, YT-300/600
YT-500/999
Electric Principle Drawing
Be
sure
to fix 10
Amp
fuse
or air switch on
the loop
of power supply when
using this
cable winch
.
Environmental Protection
Discarded electric
appliances are
recyclable
and should
not be discarded in
the domestic
waste!
Please
actively support
us in
conserving
resources
and protecting
the
environment
by returning this
appliance
to the
collection
centres
(if
available).
Electric principle drawing
Be sure to fix 10 Amp fuse or air switch on the loop of power