8 Maintenance
To ensure the best maintenance and/or transportation procedure, please observe the following
procedure:
1. Empty the fuel tank.
2. If remainders are still present, pour in clean fuel and empty it again
3.
Close the tank filler plug, dispose of the fuel as per the applicable regulations.
4. To ensure proper generator maintenance, keep it levelled to prevent fuel leaks, keep it in a dry place and protect from
getting damaged.
9 Display errors
See figure 1, No. 2, B
Error code
Possible cause
Solution
F0
Operation error
The ON/OFF switch is turned ON when the
generator is plugged
After disconnecting the generator, see that the
switch is in the OFF position, plug the generator in
and turn the switch ON
F1
Photocell error
No fuel
Turn the switch OFF, refill the fuel tank
Fuel is contaminated
Turn the switch on OFF, empty and refill the fuel
tank. Clean the filter using clean fuel, do not
damage the filter (see chapter 7)
Photocell is dirty or damaged
Contact the technical service center
Fuel filter is dirty
See chapter 7
Ignition error
Contact the technical service center
F2
Temperature control sensor error
Interrupted cable
Contact the technical service center
Sensor is damaged
Contact the technical service center
F3
Thermostat error
Internal generator overheating
Turn the generator OFF, wait until it is cooled down
Anti-tilting sensor action
Replace the heater on a level and stable surface
LO
External temperature below -9 °C
Normal condition
CH
Continuous operation (55 °C)
Normal condition