background image

9 de 11 

 

 

 

 TROUBLESHOOTING  

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

BURNER AND/OR PILOTS NOT 
TURN ON 

GAS SUPPLY TO COOKING 
EQUIPMENT IS OFF 

TURN ON GAS SUPPLY 

UNIT PRODUCING CARBON 
DEPOSITS 

GAS TYPE 

VERIFY CORRECT GAS 

GAS SUPPLY PRESURE 

CONTACT LOCAL GAS SUPPLIER 

PRIMARY AIR NOT ADJUSTED 
PROPERLY 

ADJUST AIR SHUTTER 

ORIFICE TOO BIG 

VERIFY ORIFICE SIZE 

PILOT WILL NOT REMAIN LIT 

PILOT FLAME NOT ADJUSTED  

ADJUST PILOT FLAME 

DRAFT CURRENTS NEAR 
EQUIPMENT 

FIX DRAFT 

NOT ENOUGH VENTILATION 

CONTACT HVAC CONTRACTOR 

DEBRIS OR GREASE CLOGGING 
PILOT BURNER 

CLEAN DEBRIS AND GREASE 
FROM PILOT BURNER 

EXCESSIVE FLARE-UP 

OVERLOAD OF OIL AND 
LEFTOVERS  

CLEAN AND PREPARE PAN 

NOT HEATING PROPERLY 

ORIFICES DIRTY/CLOGGED 

CLEAN ORIFICE, MAKE SURE 
THERE IS NO RESTRICTION IN THE 
ORIFICE BURNER 

LOW GAS PRESSURE 

INCREASE GAS PRESSURE TO 5” 
WC (NAT) OR 10” WC (L.P.)

 

GRATES DIRTY/CLOGGED 

CHECK AND CLEAN TOP GRATES 

IF THE VENTILATION IS TO 
STRONG IT WILL DRAFT HEAT 
FROM THE COOKING/BROILING 
SURFACE 

CALL HVAC CONTRACTOR 

Содержание Sierra SRSP-18

Страница 1: ...L INSTRUCTIONS INSTALLATION OPERATION MAINTENANCE STOCK POT RANGE SRSP 18 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 ...

Страница 2: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les in...

Страница 3: ...nit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspected prior to the carrier leaving your premises Damage must be noted in writing on the BOL and pictures must be taken at this time For any goods shipped pre...

Страница 4: ...ction is extremely dangerous LIGHTING Initial pilot lighting CAUTION When lighting pilots and checking for leaks do not Stand with your face close to the combustion chamber All Sierra appliances are adjusted and tested before leaving the factory effectively matching them to sea level conditions Adjustments and calibrations to assure proper operation may be necessary on installation to meet local c...

Страница 5: ...movable appliances there is a restraining device at the rear of the unit If disconnection of the restraint is necessary reconnect the restraint after the appliance has been returned to its originally installed position CLEANING DAILY Clean top grate s with warm water mild cleaner and wire brush Clean and brush off debris from and around the burner area Empty and clean grease pan Griddle plates sho...

Страница 6: ...r during the day and a stainless steel liquid cleaner at the end of the day To remove encrusted materials soak in hot water to loosen the material and then use a wood or nylon scraper Contact the factory factory representative or a local service company to perform repairs INSTALLATION OF LEGS LEGS ASSEMBLY Mount Legs on bottom of product the appliance may be further leveled with adjustment in the ...

Страница 7: ...nstallation please read instructions completely and carefully Do not remove permanently affixed labels warnings or plates from the product Please observe all local and national codes and ordinances Installation must conform with local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 latest edition In Canada installation should conform to installation codes for gas burn...

Страница 8: ... air conditioning system can produce a slight vacuum in the room and or cause air drafts either of which can interfere with the pilot or burner performance and could be difficult to diagnose Air movement should be checked during installation Air openings or baffles may have to be provided in the room if pilot or burner outage problem persists RATING PLATE Information on this plate includes the mod...

Страница 9: ...LAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GAS PRESSURE INCREASE GAS PRESSURE TO ...

Страница 10: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...

Страница 11: ... 11 514 737 9701 888 275 4538 sales mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canadá H4P 2P9 786 600 4687 844 218 8477 sales mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...

Отзывы: