Step 5. While components are soaking in the solution, use a soft bristle brush to clean
ice zone surface of bin. Clean interior of door, door rail, bin and evaporator
mounting bracket thoroughly and rinse them with clean water.
Step 6. Replace all removed parts after cleaning
Step 7. Set the switch to the WASH position to start automatic cleaning. Water is supplied
automatically.
Add 40ml of cleaner to the water trough.
(Place the switch in the OFF position when adding cleaner to the water trough)
Step 8. Wait until the cleaning cycle is complete (approximately 21 minutes) then place the
switch in the OFF position. Turn the switch back into the WASH position and
repeat the wash cycle if there is cleaner residue remaining in the water trough.
Step 9. Lime scale and mineral deposits should disappear when cleaning and rinsing is
complete. If foam is found in the water trough and the rinse is incomplete, repeat step 8.
Step 10. Step 10 is sanitization.Repeat monthly.
All components in step 3 need to soak into a solution of 5 liters of sanitizer
and water for 10 minutes.
Pour solution over the larger parts. Rinse the parts thoroughly.
Use running tap water only for rinse to prevent contamination.
Air dry parts, do not use a cloth or sponge.
Step 11. Use solution of sanitizer and water. Use a cloth or soft bristle brush
to clean ice zone surface of the bin. Clean bin door, door rail, storage bin
and evaporator mounting bracket thoroughly and rinse with running tap
water to prevent contamination.
Step 12. Replace the part. Place the switch in OFF position.
Step 13. Set the switch to WASH position to start automatic cleaning.
Water is supplied automatically.
Add 30ml of sanitizer to the
w
ater trough.
Step 14. Wait until the sanitization cycle is complete (approximately 21 minutes) then place
the switch in the OFF position. Turn the switch back in WASH and
r
epeat
the sanitiz
ing
cycle if sanitizer residue still remains in the water trough.
Step 15. Set the switch to the ICE position. The ice machine will start the ice making cycle.
Discard all ice made from the first cycle.Use ice from the second cyle.