AccessZone ® - GC500 Series – GC501-GC504 User Manual
7.3
How to enter System Commands – Configuration Mode
The system commands (adding/deleting users and changing system settings) can be executed
from any Bluetooth enabled mobile phone by temporarily changing the mobile phones friendly
name.
After entering a command and the Master PIN code the system gives a short beep to indicate that
the command has been accepted and executed and restarts the 10 minute configuration period.
The next command can be entered, or wait for the termination of the configuration period or
power cycle the device to startup in normal operation.
Note!
3 short beeps indicate when to use the Master PIN code instead of the normal access PIN code.
Follow these steps to execute commands:
Steps:
1) Set system into configuration mode. Refer to section 7.2 How to enter Configuration Mode
2) Enable Bluetooth on mobile phone and set it to hidden
3) Enter the required system command on the mobile phone and click save. Refer to section8
System Commands for available commands
4) Set the mobile phone to visible
5) Place mobile phone within the detection range of the system
6) Wait for 3 short beeps
7) Enter Master PIN code (e.g. 12345678) when prompt
8) Wait for beep for successful execution of the command
9) Set the mobile phone to invisible/hidden
10) Erase command from mobile phone
If more commands must be executed repeat step 2) – 9)
7.3.1
If the system doesn’t respond to a command:
System is not in configuration mode any more (10 minutes time out)
- Check Blue LED - flashing? Else re-enter configuration mode. Refer to section 7.2 How to
enter Configuration Mode
The administrator is outside the allowed configuration range
- Administrator must get closer to the system
The command has already been executed
- Try change one of the parameters or try another command
The command is not valid
- Wrong number of parameters, wrong parameter values and/or wrong command length
(e.g. spaces at the end)
The system time out waiting reading the command or connection to mobile failed
- Wait for next detection