MV Heating UK Ltd
Installation Angle
All positions suggested are examples. Other locations are possible so long as
they correspond to the proper installation guidelines and requirements.
1.
Heater air intake
2.
Glow pin position
3.
Direction of air flow
Figure
VI
Figure VI shows the ideal installation position of the heater; with exhaust
pointing downward. Depending on its location it can be tilted by 30° with the
air flow and hot air outlet facing the bottom. It can also be tilted on its
longitudinal axis by 90° so long as the glow pin position points upward. During
usual operation the heater can deviate by 15° each way with vehicle
movement without impaired function of the heater.
1
30°
3
90°
2
1