MV Heating MV Airo 2 Скачать руководство пользователя страница 2

+44 (0)23 8052 2345

 

 

 

 

MV Heating UK Ltd 

Disclaimer: 

This manual is intended to give an overview of the internal workings of MV 
diesel heaters. As such, all work should be carried out by trained 
professionals at their own discretion. Any action you take upon the 
information in this manual is strictly at your own risk, and MV Heating will not 
be liable for any losses and damages in connection with the use of this 
information. Under no circumstances shall MV Heating or its affiliates, 
suppliers, or installers be liable for any indirect, incidental, consequential, 
special or exemplary damages, arising out of or in connection with these 
manuals. We do not take any warranties about the completeness, reliability 
and accuracy of this information. MV Heating assumes no responsibility or 
liability for any errors or omissions from these manuals. 

 

 

Содержание MV Airo 2

Страница 1: ...MV Heating UK Ltd Unit 6 Second Avenue Business Park Millbrook Southampton SO15 0LP MV Heating UK LTD 44 0 2380 522345 MV Airo 2 WORKSHOP MANUAL ED 1 01...

Страница 2: ...d MV Heating will not be liable for any losses and damages in connection with the use of this information Under no circumstances shall MV Heating or its affiliates suppliers or installers be liable fo...

Страница 3: ...art 2 The Overheat Sensor 9 Part 3 The E C U 10 Part 4 The Air Motor 11 Part 5 Burner Glow Pin and Combustion Chamber 12 Part 5 Cont d Burner Glow Pin and Combustion Chamber 13 Part 5 Cont d Burner Gl...

Страница 4: ...m the bottom of the heater 8 Remove the four M6 nuts and washers from the base of the heater 9 Remove the heater and discard the mounting gasket Heater Installation To reinstall the heater back into p...

Страница 5: ...44 0 23 8052 2345 4 MV Heating UK Ltd Heater Cases Diagram 6 1 3 4 2 5 Figure 1 1 Inlet Cap 2 Outlet Cap 3 E C U Cover 4 Top Cover 5 Bottom Cover 6 Grill...

Страница 6: ...UK Ltd Internal Structure Diagram Figure 2 1 Heat Exchanger 2 4 Hole Gasket 3 Combustion Tube 4 Burner Assembly 5 5 Hole Gasket 6 Air Motor 7 Insulation Bushes 8 E C U 9 Air Fan 10 Glow Pin 11 Overhea...

Страница 7: ...44 0 23 8052 2345 6 MV Heating UK Ltd ECU Connections Diagram Figure 3 1 Fan Motor 2 Glow Pin 3 Overheat Sensor 4 Fuel Pump 5 Unused 6 Main Wiring Harness 6 1 2 3 4 5...

Страница 8: ...d be cleaned with appropriate cleaning fluid and blown dry with pressurized air Any sealing compound on parts must be carefully and completely removed before attempting to refit All disassembled parts...

Страница 9: ...ove the top case 1 4 by sliding away from the bottom case 5 Remove the bottom case 1 5 by pulling away from air motor lugs first Refitting the Cases 1 Make sure all 4 insulating bushes 4 7 are located...

Страница 10: ...blue wires 3 Free the wires from around the E C U hook 4 Slide the overheat sensor off the heat exchanger 2 1 Using a small flat bladed screwdriver as necessary to lever it off Refitting the Overheat...

Страница 11: ...ews holding the E C U in place 5 The E C U can now be removed inspected and replaced as necessary Refitting the E C U 1 Place the E C U back into position and tighten the 3 x Phillips head screws back...

Страница 12: ...o that the combustion intake clears the gap on the heat exchanger 2 1 4 The air motor gasket 2 5 can be removed and discarded once the air motor is clear Refitting the Air Motor 1 Place a new air moto...

Страница 13: ...r motor Part 4 2 Gently push the glow pin grommet fully through toward the burner 3 Using an Allen key remove the 4 x 3mm hex bolts from the burner 2 4 and place to one side 4 The burner and combustio...

Страница 14: ...d screwdriver to loosen the screw holding the glow pin 2 10 in place 2 Gently remove the glow pin from out of its housing the glow pin can be tight to remove 3 The burner and glow pin can now be inspe...

Страница 15: ...r the right way up inside the heat exchanger 3 Place the burner assembly inside the combustion chamber and reinsert the 3 x 5 5mm hex screws back into the burner and tighten to 0 6 0 06 Nm 4 Feed the...

Страница 16: ...Z 004 5 5 Hole Gasket A2Z 005 6 Air Motor 12V 24V A2C 006 A2A 006 7 Insulation Bushes A25Z 007 8 E C U 12V 24V A2C 009 A2A 009 9 Air Fan A2Z 010 10 Glow Pin 12V 24V A2C 014 A2C 014 11 Overheat Sensor...

Страница 17: ...44 0 23 8052 2345 16 MV Heating UK Ltd Notes...

Страница 18: ...44 0 23 8052 2345 17 MV Heating UK Ltd...