+44 (0)23 8052 2345
12
MV Heating UK Ltd
Part 5: Burner, Glow Pin, and Combustion Chamber
Tools:
•
1 x Small Flat-Bladed Screwdriver
•
1 x 5.5mm Socket Screwdriver
•
1 x Small Phillips Head Screwdriver
Removing the Assembly:
1)
Remove the cases (
Part 1
) remove the E.C.U. (
Part 3
) and remove the air
motor (
Part 4
).
2)
Gently push the glow pin grommet fully through toward the burner.
3)
Using an Allen key, remove the 4 x 3mm hex bolts from the burner (
2:4
),
and place to one side.
4)
The burner and combustion chamber (
2:3
) will be connected to each
other and can be partially lifted out of the heat exchanger.
5)
Separate the two using a small flat-bladed screwdriver and remove both
parts from the heat exchanger (
2:1
).
6)
Remove the 4-hole gasket (
2:2
) from inside the heat exchanger and
discard.
Содержание MV Airo 2
Страница 17: ...44 0 23 8052 2345 16 MV Heating UK Ltd Notes...
Страница 18: ...44 0 23 8052 2345 17 MV Heating UK Ltd...