8.2.1.2
Iron oxide (rust) caused, for example, by mechanical loading, wear, road salt deposits, insufficient or
neglected care. Care measures by means of lightly rubbing down the damaged surface with grinding wool
grain A 280 medium fine. Paint treated surfaces.
Recommended frequency: At least 1 x yearly. Check during basic cleaning, and treat if need be
8.2.2
Screws, nuts, washers
When performing basic cleaning of the units immediately check all screws, nuts and washers for correct fit. In the
event of rust, brush with a brass brush applying light pressure and clean and spray protective wax after cleaning.
Recommended frequency: At least 4 x yearly. Check and treat if necessary
8.2.3
Powder coated surfaces
Damage due to mechanical or other effects are to be treated as soon as they are detected in order to prevent
impairments or infiltration of the powder coating. Care or improvement measures are to be carried out as follows:
light rubbing with emery cloth, grain 120 or brass brush (do not use a wire brush!) followed by cleaning and
degreasing with brake cleaner. Apply the touch-up paint to the damaged points with a brush, such as, for example
Touch-up paint RAL 7016 anthracite grey, air-dried.
Recommended frequency: At least 2 x yearly. Check during basic cleaning and treat if necessary
8.2.4
Disposal
The materials we have named are to be disposed off in accordance with the respective manufacturer’s
recommendations. For proper disposal the local authorities, such as municipal authorities, environmental
protection office or trade supervisory council, are to be informed – insofar as residual substances from car oils,
batteries or similar have been collected.
Recommended frequency: As required
8.3 Protection (to be performed by the customer)
Premature corrosion damages to the protection coating can furthermore be prevented by:
8.3.1
limiting exposure to dampness and humidity (e.g. by removing the snow clumps from vehicle wheel housings)
8.3.2
seeing to appropriate site aeration (i.e. to prevent the relative atmospheric humidity levels from reaching <
80%, particularly in the colder months of the year)
8.3.3
performing regular and appropriate cleaning of all the top surface of the platform, ground and the pit floor
8.3.4
draining away any water accumulating on the ground or in the pit and by removing dirt and debris from the
pit sump and/or from the pit drainage channels
8.3.5
the regular and appropriate reconditioning of any visible surface alterations