![Mutec MF3000 Ex Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/mutec/mf3000-ex/mf3000-ex_service-manual_1860035006.webp)
11/2018
6
3. General information for installation and operation
Fig. 1
Fig. 2
Identification in accordance with directive 2014/34/EU for use in dust explosive areas:
Explosion protected
II
Equipment group: equipment for non-mining applications
1/2
Equipment category: very high /
high level of protection (equipment with partition wall)
D
Type of explosive atmosphere: dust
Identification of type of protection:
Ex
Explosion protection
ta/tb
Type of protection: protection by enclosures,
incl. level of protection: ta/tb (equipment with partition wall)
IIIC
Dust group: conductive dust
T135°C
Maximum surface temperature: 135°C
Da/Db
EPL (Equipment Protection Level): Very high / high level of protection (dust)
Identification in accordance with directive 2014/34/EU for use in gas explosive areas:
Explosion protected
II
Equipment group: equipment for non-mining applications
3
Equipment category: normal level of protection
G
Type of explosive atmosphere:
gas, vapor, mist
Identification of type of protection:
Ex
Explosion protection
ec
Type of protection: increased safety
IIC
Gas group: highest requirements (most explosive gases)
T4
Temperature class: maximum surface temperature = 135°C
Gc
EPL (Equipment Protection Level): Enhanced level of protection (gas)
CE mark
This product meets the specifications according to the EMC-directive 2014/30/EU and the ATEX-
directive 2014/34/EU.
Содержание MF3000 Ex
Страница 10: ...11 2018 10 5 Terminal connections Fig 4 ...