![Mutec MF3000 Ex Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/mutec/mf3000-ex/mf3000-ex_service-manual_1860035013.webp)
11/2018
13
7. Mounting and Assembly
Scope of delivery
• Flow sensor
MFS3000-*-Ex*
• Transmitter
MFI3000
, DIN-rail mountable
• Software
MF-SMART
for Windows
• Installation manual
• USB interface cable (USB-A to USB_B mini)
• Welding branch for
the flow sensor (optional)
Preparation for sensor assembly
A welding device and a drilling machine (drill = 18 mm ø) are needed for the installation. Some important
notes should be observed, regarding the choice of the optimal installation position. The welding branch
can be installed into a horizontal transport line or into a vertical free fall line.
The assembly is always expedient into a free fall line. The vertical line tracing has to be preferred upward
in case of air conveying lines.
The distances of the inlet/outlet pipe to the
MFS3000-*-Ex*
shouldn’t fall below the following distances
as a multiple of the nominal diameter (DN).
Fig. 9
Fig. 10
9 0 , 0 0 °
9 0 , 0 0 °
Содержание MF3000 Ex
Страница 10: ...11 2018 10 5 Terminal connections Fig 4 ...