background image

 

Step 5: Disable and enable EPO function 

Keep the pin 1 and pin 2 closed for UPS normal operation. To activate EPO function, cut the wire 
between pin 1 and pin 2. 

 

 

Step 6: Turn on the UPS   

Press the ON/Mute button on the front panel for two seconds to power on the UPS. 

Note: The battery charges fully during the first five hours of normal operation. Do not expect 
full battery run capability during this initial charge period. 
 

Step 7: Install software 

For optimal computer system protection, install UPS monitoring software to fully configure UPS 
shutdown. You may insert provided CD into CD-ROM to install the monitoring software. If not, 
please follow steps below to download and install monitoring software from the internet:

 

1. Go to the website 

http://www.power-software-download.com

 

2. Click ViewPower software icon and then choose your required OS to download the software.   
3. Follow the on-screen instructions to install the software. 
4. When your computer restarts, the monitoring software will appear as an orange plug icon 
located in the system tray, near the clock. 

 

Step 8: External battery connection

 (for long-run models only) 

Follow below chart to make external   
battery connection. 

                                   

 

It’s in closed status for UPS 

normal operation.   

Содержание POWERMUST 1008 ONLINE LCD

Страница 1: ...PowerMust 1008 Online LCD RM PowerMust 2016 Online LCD RM PowerMust 3024 Online LCD RM Online UPS User Manual EN...

Страница 2: ...s 3 2 Installation and setup 4 2 1 Rear panel view 4 2 2 Setup the UPS 5 3 Operations 7 3 1 Button operation 7 3 2 LCD Panel 7 3 3 Audible Alarm 9 3 4 LCD display wordings index 9 3 5 UPS Setting 9 3...

Страница 3: ...er them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed sh...

Страница 4: ...must be kept well away from the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the...

Страница 5: ...rMust 3024 Online LCD Standard PowerMust 3024L Online LCD Long run 2 1 Rear panel view PowerMust 1008 L Online LCD PowerMust 2016 L Online LCD PowerMust 3024 L Online LCD PowerMust 1008 L Online LCD R...

Страница 6: ...5 12 Output circuit breaker...

Страница 7: ...or the wiring configuration a Remove the small cover of the terminal block b Suggest using AWG14 or 2 1mm2 power cords Suggest using WG12 10 or 3 3mm2 5 3mm2 power cords for NEMA type c Upon completio...

Страница 8: ...tware to fully configure UPS shutdown You may insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring software from the in...

Страница 9: ...e UPS will be in standby mode under power normal or transfer to Bypass mode if the Bypass enable setting by pressing this button Confirm selection key Press this button to confirm selection in UPS set...

Страница 10: ...6 50 51 75 and 76 100 Indicates overload Indicates the load or the UPS output is short circuit Programmable outlets information Indicates that programmable management outlets are working Mode operatio...

Страница 11: ...reviation Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS Low loss BAT Battery CF Converter EP EPO FA Fan TP Temperature CH Charger 3 5 UPS Setting There are three paramete...

Страница 12: ...ency setting Interface Setting Parameter 2 3 Output frequency setting You may set the initial frequency on battery mode BAT 50 presents output frequency is 50Hz BAT 60 presents output frequency is 60H...

Страница 13: ...240 VAC models 230 264 setting the high voltage point in parameter 3 from 230Vac to 264Vac For 110 115 120 127 VAC models 120 132 setting the high voltage point in parameter 3 from 120Vac to 132Vac L...

Страница 14: ...ry mode When the input voltage is beyond the acceptable range or power failure and alarm is sounding every 4 second UPS will backup power from battery Bypass mode When input voltage is within acceptab...

Страница 15: ...cond Battery is not connected Sounding every second Over Charge Sounding every second Site wiring fault Sounding every second EPO enable Sounding every second Fan Failure Sounding every second Over te...

Страница 16: ...cted Check if all batteries are connected well Fault code is shown as 27 and the icon is lighting on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is fault...

Страница 17: ...p time is shorter than nominal value Batteries defect Contact your dealer to replace the battery The icon and the warning code flashing on LCD display and alarm is sounding every second Fan is locked...

Страница 18: ...Harmonic Distortion 3 THD Linear Load 6 THD Non linear Load 4 THD Linear Load 7 THD Non linear Load AC Mode to Batt Mode Zero Transfer Time Inverter to Bypass 4 ms Typical Waveform Batt Mode Pure Sin...

Отзывы: