13
9. Connect the other ends of the coiled hoses to the neck plug. It
does not matter which hose connects to which plug. Figure 15
shows the correct configuration.
10. Ensure your configuration matches Figure 16, that shows the two
coiled pneumatic hoses correctly attached to the control box and
the neck plug.
Figure 15
Figure 16
11. Connect high-pressure air source to the input side of the control
box. The air pressure should be no greater than 150 psi.
NOTE: Ensure the control lever is set in the off position
before the high-pressure air is connected.
12. The control box has one pressure gauge and two controls. The
black control lever has three positions as labeled on the control
box. The knurled knob can be turned to restrict the airflow
traveling into the dry suit.
13. Move the control lever to the fast position. The suit should inflate
rapidly. Once the suit appears ¾ inflated, move the lever to the
slow position. Turn the knurled knob to restrict the airflow rate
until the suit inflates up to 12 in. water pressure. Twist the knurled
knob further to hold pressure inside the suit at 12 in. water.
Figure 17
Figure 18