ARCLED7136
8
Number of
DMX channels
Start address
(example)
DMX Address
occupied
Next possible start
address for unit No. 1
Next possible start
address for unit No. 2
Next possible start
address for unit No. 3
9
33
33-41
42
51
60
3.4 Operation in automatic mode
If no DMX control signal is present at the DMX INPUT, the unit independently runs through its show pro-
gramme provided that the blackout mode is switched off:
•
Press the button MODE so many times until the display shows
[
AUTO
]
, then press the button ENTER.
•
Press the button UP to scroll to the desired program
(
AT1F
-
AT8F
o
AT1O
-
AT8O
) and press the button
DOWN
to switch between the modes
“O” e “F” (
AT1O
-
AT1F
).
•
To confirm, press the button ENTER. The unit will operate in automatic mode.
•
Set the speed of execution programs (
SP01
-
SP25
), through the buttons UP and DOWN.
•
Set the duration of execution (
T008
-
T255
), through the buttons UP and DOWN.
3.5 Master/Slave Mode
This mode will allow you to link up the units together without a controller. Choose a unit to function as the
Master (
MAST
). The unit must be the first unit in line; other units will work as slave (
SLAV
) with the same
effect.
•
Press the button MODE so many times until the display shows
[
MAST
or
SLAV
], depending on whether
you want to set the unit as master or slave.
•
Select the desired program (Auto or Custom), and press the button ENTER to confirm.
•
Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the
units. For longer cable runs we suggest a terminator at the last fixture (se
e page 11).
3.6 Linking
Several units may be interconnected in order to control all further slave units to the same effect of the
master unit.
1. Connect the DMX OUT of the master unit via 3-pole XLR cable to the DMX IN of the first slave unit.
2. Connect the DMX OUT of the first slave unit to the DMX IN of the second slave unit, etc. until all units are
connected in a chain.
3.7 DMX Mode
•
Press the button MODE so many times until the display shows
[
D512
].
•
Press the buttons UP and DOWN to select the desired value.
•
After the setting value is automatically saved.
3.8 DMX addressing without ID addressing
To able to operate the ARCLED7136 with a light controller, adjust the DMX start address for the first a DMX
channel. If e. g. address 33 on the controller is provided for controlling the function of the first DMX chan-
nel, adjust the start address 33 on the ARCLED7136. The other functions of the light effect panel are then
automatically assigned to the following addresses. An example with the start address 33 is shown below:
•
For addressing without ID addressing, press the button MODE so many times until shows
[
IDOF
].
NOTE: The ID address has not been set so therefore when using the controller channel 9 must be inactive
(CH9=0).
Содержание ProLights ARCLED7136
Страница 1: ...I GB Manuale Utente User Manual ARCLED7136 ARCHITAINMENT LED PROJECTOR...
Страница 2: ...REV 002 04 10...
Страница 17: ......
Страница 18: ......
Страница 33: ......
Страница 34: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......