background image

Operation

User manual 59507_hdb_en_12

 43 / 51

7.3

Diagnostic

7.3.1

Vendor-specific IO-Link events

In addition to the vendor-specific IO-Link events listed here, the standard 

events of the IO-Link specification also apply, version see chapter 1.5.3 

"Specifications".

Tab. 7-5: IO-Link events

Event 

code

Event type

Description

0x4000

Error

The device shows a temperature fault - overload.

0x4210

Warning

The device shows a temperature over-run.

0x4220

Warning

The device shows a temperature under-run.

0xFF91

Notification

The device requests a data storage upload from the master.

0x5100

Error

General power supply fault (US) - below shutdown voltage.

0x5110

Warning

Primary sensor supply voltage (US) is over-run.

0x5111

Warning

Primary sensor supply voltage (US) is under-run.

0x1830

Warning

Secondary sensor supply voltage (UA) is over-run.

0x1831

Warning

Secondary sensor supply voltage (UA) is under-run.

0x1832

Error

Secondary power supply fault (UA) - below shutdown volt-

age.

0x7710

Error

Short-circuit detected on a specific channel.

0x8CA0

Error

DIO pin current overload/ shortcircuit - Port 0 Pin 4.

0x8CA1

Error

DIO pin current overload/ shortcircuit - Port 0 Pin 2.

0x8CA2

Error

DIO pin current overload/ shortcircuit - Port 1 Pin 4.

0x8CA3

Error

DIO pin current overload/ shortcircuit - Port 1 Pin 2.

0x8CA4

Error

DIO pin current overload/ shortcircuit - Port 2 Pin 4.

0x8CA5

Error

DIO pin current overload/ shortcircuit - Port 2 Pin 2.

0x8CA6

Error

DIO pin current overload/ shortcircuit - Port 3 Pin 4.

0x8CA7

Error

DIO pin current overload/ shortcircuit - Port 3 Pin 2.

0x8CA8

Error

DIO pin current overload/ shortcircuit - Port 4 Pin 4.

0x8CA9

Error

DIO pin current overload/ shortcircuit - Port 4 Pin 2.

0x8CAA Error

DIO pin current overload/ shortcircuit - Port 5 Pin 4.

0x8CAB Error

DIO pin current overload/ shortcircuit - Port 5 Pin 2.

0x8CAC Error

DIO pin current overload/ shortcircuit - Port 6 Pin 4.

0x8CAD Error

DIO pin current overload/ shortcircuit - Port 6 Pin 2.

0x8CAE Error

DIO pin current overload/ shortcircuit - Port 7 Pin 4.

0x8CAF

Error

DIO pin current overload/ shortcircuit - Port 7 Pin 2.

0x8CD0

Error

Power pin current overload/ shortcircuit - Port 0 Pin 1.

0x8CD1

Error

Power pin current overload/ shortcircuit - Port 1 Pin 1.

0x8CD2

Error

Power pin current overload/ shortcircuit - Port 2 Pin 1.

0x8CD3

Error

Power pin current overload/ shortcircuit - Port 3 Pin 1.

0x8CD4

Error

Power pin current overload/ shortcircuit - Port 4 Pin 1.

0x8CD5

Error

Power pin current overload/ shortcircuit - Port 5 Pin 1.

0x8CD6

Error

Power pin current overload/ shortcircuit - Port 6 Pin 1.

0x8CD7

Error

Power pin current overload/ shortcircuit - Port 7 Pin 1.

Содержание 59504

Страница 1: ...ENGLISH MANUAL for devices of the MVP8 series Art No 59504 59507 59604 59607 Murrelektronik GmbH...

Страница 2: ...E Translation of the original instructions This document applies to the following products Document status Name Art No MVP8 P3 DIO8 8xM8 3 IOLA12 B0 59507 MVP8 P3 DIO8 8xM8 3 IOLA12 E0 59607 MVP8 P3 D...

Страница 3: ...n Code 11 3 2 Module structure 12 3 3 PIN assignment 13 3 3 1 IO Link Class A 13 3 3 2 IO Link Class B 13 4 Technical Data 14 4 1 Art No 59507 14 4 1 1 Electrical data 14 4 1 2 Environmental character...

Страница 4: ...tion 30 6 1 Connection lines 30 6 1 1 Ensure tight seal 31 7 Operation 32 7 1 LED indication 32 7 1 1 LED indication US and IO Link 32 7 1 2 LED indication UA 33 7 1 3 LED indication for inputs and ou...

Страница 5: ...lossary You can find explanations of the terms abbreviations used at https www murrelektronik com products industries glossary 1 1 Service and support Sales and distribution Our sales employees in the...

Страница 6: ...mponents into the correct recycling line Disposal The product can be returned to Murrelektronik GmbH free of charge for dis posal The same is true for the original packaging and any batteries or power...

Страница 7: ...s CAUTION Low risk danger Failure to observe this warning can lead to mild to moderate injuries NOTICE Possible material damage Failure to observe the warning may cause damage to the device and or the...

Страница 8: ...mpanies and institutions are used in this docu mentation 1 5 3 Specifications The features of the IO Link Specification version 1 1 3 are supported as well IO Link c o PROFIBUS Nutzerorganisation e V...

Страница 9: ...io interference may occur if the module is used in a domestic or mixed en vironment Follow standards for domestic or mixed environments 2 2 1 Foreseeable misuse Foreseeable misuse The module must not...

Страница 10: ...7 Art No 59504 59604 IO Link hub in 30 mm plastic housing 1 x M12 IO Link class A 8 x M8 I O 8 configurable digital inputs outputs IO Link hub in 30 mm plastic housing 1 x M12 IO Link class B 8 x M8 I...

Страница 11: ...DIO8 8xM8 3 IOLA12 E0 MVP8 P3 Product family module size DIO D Digital I Input O Output 8xM8 3 Number and size of ports number of pins IOLA IOL IO Link A Class A E0 Extended Firmware Features MVP8 P3...

Страница 12: ...Module structure and port designations Art No Port designation Explanation 59507 59607 X0 X7 Digital inputs and outputs US XZ1 Module supply IO Link Class A 59504 59604 X0 X3 Digital inputs and output...

Страница 13: ...n 3 0 V US L Pin 4 C Q IO Link Pin 5 n c DIO X0 X7 M8 female connectors Pin 1 24 V US Pin 3 0 V US Pin 4 DIO US IO Link XZ1 M12 male connectors Pin 1 24 V US L Pin 2 24 V UA P24 Pin 3 0 V US L Pin 4 C...

Страница 14: ...Galvanic isolation No 0 0 5 I A 1 2 5 1 5 2 30 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400 bit s Bus protocol IO Link V1 1 2 compati ble with IO Link V1 1...

Страница 15: ...rts 2 6 5 500 Hz const amplitude 1 mm acceleration 15 g Shock test EN 60068 Parts 2 27 50 g 11 ms Electrical safety Degree of protection IP68 Protection class III Degree of pollution 2 Emitted EMC int...

Страница 16: ...ronically Short circuit protection output DO Electronically Protective circuit for input Internal Suppressor diode Product reliability MTTF SN 29500 at 40 C and rated data 94 years Assembly data Weigh...

Страница 17: ...0 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400 bit s Bus protocol IO Link V1 1 2 compati ble with IO Link V1 1 3 IO Link cycle time 1 ms VendorID 0x012F DeviceID 0x0C0...

Страница 18: ...e Radio interference field strength EN 61000 6 4 Emission QP 40 dB V m 30 230 MHzQP 47 dB V m 230 1000 MHz EMC immunity Electrostatic discharge housing EN 61000 4 2 4 kV contact 8 kV air Electromagnet...

Страница 19: ...s Assembly data Weight Net 129 g Dimensions L x W x H 126 x 30 x 34 5 mm Conformity Approvals Product standard EN 61131 2 Programmable logic controllers Part 2 Compliant CE 2014 30 EU 2011 65 EU Compl...

Страница 20: ...UA 50 C see Derating 4 A Power consumption when idling 50 mA Galvanic isolation Yes 0 0 5 I A 1 2 5 1 5 2 30 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400...

Страница 21: ...ts 2 6 5 500 Hz const amplitude 1 mm acceleration 15 g Shock test EN 60068 Parts 2 27 50 g 11 ms Electrical safety Degree of protection IP68 Protection class III Degree of pollution 2 Emitted EMC inte...

Страница 22: ...ronically Short circuit protection output DO Electronically Protective circuit for input Internal Suppressor diode Product reliability MTTF SN 29500 at 40 C and rated data 86 years Assembly data Weigh...

Страница 23: ...UA 50 C see Derating 4 A Power consumption when idling 50 mA Galvanic isolation Yes 0 0 5 I A 1 2 5 1 5 2 30 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400...

Страница 24: ...068 Parts 2 6 5 500 Hz const amplitude 1 mm acceleration 15 g Shock test EN 60068 Parts 2 27 50 g 11 ms Electrical safety Degree of protection IP68 Protection class III Degree of pollution 2 Emitted E...

Страница 25: ...ronically Short circuit protection output DO Electronically Protective circuit for input Internal Suppressor diode Product reliability MTTF SN 29500 at 40 C and rated data 86 years Assembly data Weigh...

Страница 26: ...unting surface to avoid mechanical tension Provide suitable grounding Suitable installation site in terms of vibration and shock load temperature and humidity see chap 4 Technical Data Protected to av...

Страница 27: ...rect installation The fastening screws and tightening torques depend on the surface of the in stallation site Use fastening screws that are suitable for the mounting surface structure Carefully tighte...

Страница 28: ...M4 Mounting 1 Align housing 2 Slightly tighten an M4 bolt 3 Slightly tighten the second M4 bolt 4 Tighten both screws M4 to the specified tightening torque 5 Fasten the grounding strap see chapter 5...

Страница 29: ...Mounting User manual 59507_hdb_en_12 29 51 5 5 Functional ground Fig 5 4 Ground strap fastening M4 2 Nm Art No 7000 98001 0000000...

Страница 30: ...uring connection work According to IEC 60364 Protection against electric shock CAUTION Hot surface Burnings and line damage caused by touching the devices Wear thermally suitable protective gloves Onl...

Страница 31: ...aranteed if all connections are sealed with plug connectors screw plugs or sealing caps Seal unused male and female connectors Fig 6 1 Connecting cables PRODUCTS AND ACCESSORIES You will find a wide r...

Страница 32: ...S and IO Link The device has a combined LED for the IO Link status and the status of the US sensor supply The IO Link status is mapped by the green LED chip and the US status by the red LED chip This...

Страница 33: ...O Link in IDLE status Firmware update completed success fully Green Flashing 1 Hz IO Link in status PREOPERATE OP ERATE update is not yet performed Red Permanently on Update failed Green Red Flashing...

Страница 34: ...e update is being per formed 0 ISDU index DPP index Object name Access Length in bytes Meaning default value Identification DIO8 Art No 59507 DIO8 Art No 59607 0x0000 0x00 MasterCommand W 1 0x01 Maste...

Страница 35: ...during production 0x0016 HardwareRevision R 64 e g 01 00 0x0017 FirmwareRevision R 64 e g V 1 00 00 0x0018 ApplicationSpe cificTag R 16 32 User specific designation e g System 3 Port 4 0x0019 Function...

Страница 36: ...R variable 0x000F PDOutputDescriptor R variable 0x0010 VendorName R 64 Murrelektronik GmbH 0x0011 VendorText R 64 www murrelektronik com 0x0012 ProductName R 64 MVP8 P3 DIO4 DIO4 8xM8 3 IOLB12 B0 MVP...

Страница 37: ...DeviceSta tus R variable 6 x octet 1 EventQualifier octet 2 3 EventCode 0x0028 ProcessDataInput R PD length 0x0029 ProcessDataOutput R PD length 0x0031 0x003F Reserved for pro files ISDU index DPP ind...

Страница 38: ...ng master 0x0000 0x0062 Diagnosis Disable General Diagnosis R W 16 Configurable diagnosis 0 active 1 disabled Subindex 1 IO Link Event Code transmission to Master Subindex 2 US Diagnosis low voltage S...

Страница 39: ...Subindex 7 X6 Pin 4 Subindex 8 X7 Pin 4 Setting per channel subindex 0 OFF no filtering 1 1 s 2 10 s 3 100 s 4 1 ms 5 2 ms 6 3 ms 7 5 ms 8 10 ms 4 0x0090 Outputs Short Circuit Re covery Behavior R W 1...

Страница 40: ...is shown inside the input process data 0x0000 0x0061 Identification User Defined Serial Number R W 16 User defined serial number This can be used to ensure that a device is not connected to the wrong...

Страница 41: ...bindex 2 X1 Pin 4 Subindex 7 X6 Pin 4 Subindex 8 X7 Pin 4 Setting per channel subindex 0 0 ms OFF 1 10 ms 2 20 ms 3 30 ms 255 reserved 0 0x0082 Inputs Input Debounce Filter Time R W 16 Setting of the...

Страница 42: ...h individual output channel in the event of a loss of communication with the master Subindex 1 X0 Pin 4 Subindex 2 X1 Pin 4 Subindex 7 X6 Pin 4 Subindex 8 X7 Pin 4 Setting per channel subindex 0 logic...

Страница 43: ...cuit Port 1 Pin 4 0x8CA3 Error DIO pin current overload shortcircuit Port 1 Pin 2 0x8CA4 Error DIO pin current overload shortcircuit Port 2 Pin 4 0x8CA5 Error DIO pin current overload shortcircuit Por...

Страница 44: ...Pin4_X6 5 Pin2_X6 6 Pin4_X7 7 Pin2_X7 Byte 2 Diagnostic Bit Description 0 Error Warning at power supply too low or high 1 Error Warning because of temperature rating threshold can be defined inside o...

Страница 45: ...e identification bits e g for tool change applications 0 not used 1 255 ID value is read out from object Byte 0 Outputs X0 X3 Bit Contact 0 Pin4_X0 1 Pin2_X0 2 Pin4_X1 3 Pin2_X1 4 Pin4_X2 5 Pin2_X2 6...

Страница 46: ...er supply too low or high 1 Error Warning because of temperature rating threshold can be defined inside object 2 Error Warning at Input Output short circuit or overload 3 DIA at channel X 0 channel 1...

Страница 47: ...utput Process Data Byte 0 Outputs X0 X3 Bit Contact 0 Pin4_X0 1 Pin2_X0 2 Pin4_X1 3 Pin2_X1 4 Pin4_X2 5 Pin2_X2 6 Pin4_X3 7 Pin2_X3 Byte 1 Outputs X4 X7 Bit Contact 0 Pin4_X4 1 Pin2_X4 2 Pin4_X5 3 Pin...

Страница 48: ...manual 59507_hdb_en_12 48 51 8 Maintenance and cleaning NOTE Replace defective or damaged devices Device cleaning Use only oil free compressed air or spirit Only use lint free materials e g leather c...

Страница 49: ...urrelektronik online shop https shop murrelektronik com Description Art No Screw Plug M12 Metal 996049 Plastic M12 screw plug VE10 58627 Metal addressing lid 55317 Grounding strap screw down set M4 40...

Страница 50: ...is technical documenta tion to create their own technical documentation For this purpose the docu mentation produced by Murrelektronik GmbH may be changed in parts or amended or copied and transferred...

Страница 51: ...NY 49 7191 47 0 49 7191 47 491 000 info murrelektronik com www murrelektronik com The information in the manual has been compiled with utmost care Liability for the correctness completeness and topica...

Отзывы: