Technical Data
User manual 9000-41011-0200000_hdb_en_20
40 / 92
4.4
Mico Pro Plug-In link
4.4.1
Electrical data
4.4.1.1
Input
4.4.2
Environmental characteristics
4.4.2.1
Climatic
4.4.2.2
Mechanical
4.4.2.3
Electrical safety
Parameter
Conditions
Value
Operating voltage
12 V
, 24 V
Input voltage range
9 V ... 30 V
Total operating current continuous
jumper
Plug-In link
40 A
Output current
40 A
Symbol Parameter
Conditions
Value
Relative humidity
No condensation
5 ... 85 %
Storage temperature
-40 ... +80 °C
Climate class
IEC/EN 60721-3-3
3K3
Ta
Surrounding air temperature
range
-25 ... +55 °C
Installation height
Above sea level,
without any restrictions
-500 m ... 2000 m
Installation height
Above sea level,
max. 32 A total operat-
ing current
2000 m ... 4000 m
Installation height
Above sea level,
max. 24 A total operat-
ing current
4000 m ... 6000 m
Parameter
Conditions
Value
Vibration test
IEC 60068-2-6:2007 Test
Fc; EN 60068-2-6:2008
sin 5 ... 17.8 Hz: 1.6
mm;
17.8 ... 500 Hz: 2.3 g
10x f
Shock test
IEC 60068-2-27:2008 Test
Ea; EN 60068-2-27:2009
1/2 sin 30 g, 11 ms
Shocks caused by rough handling (Drop test)
1 m
Parameter
Conditions
Value
Degree of protection
EN 60529
IP20
Pollution degree
2
Overvoltage category
III
Содержание Mico Pro fix 1.10