![Murr Elektronik DataPanel xtreme DB DP-34044-3 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/murr-elektronik/datapanel-xtreme-db-dp-34044-3/datapanel-xtreme-db-dp-34044-3_user-manual_1858241028.webp)
28
All PGNs are shown as module configured with no jumpers (Offset = 0)
PGN
61408 (0xEFE0) Node offset of 0
Source Address
(0x?? (CSA*))
PDU Format
239 (0xEF)
PDU Specific
224 (0xE0)
Built Message
(0x
18EFE0??
)
Command Value
84 (0x54)
Name
Data Type
Byte
Bits
Description
Command
Byte
1
Command for index pointer (which message your sending)
Mode 8A
4 bit
2
1,2,3,4
Mode 0x0=disabled, 0x1=On/Off, 0x2=Data(0-4000), 0x3=Percent(0-1000
= 0-100.0%)
Mode 8B
5,6,7,8
Byte
3
4
5
6
7
8
J1939 Output Configuration 3
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
PGN
61408 (0xEFE0)
Source Address
(0x?? (CSA*))
PDU Format
239 (0xEF)
PDU Specific
224 (0xE0)
Built Message
(0x
18EFE0??
)
Name
Data Type
Byte
Bits
Description
Command
Byte
1
Command for index pointer
Port 1A Output 1A (0-100)
2
All
Set amp range 0.0-10.0A = Data Range 0-100
Port 1A Output 1B (Not Used)
3
Port 1A Output 2A (0-100)
4
Port 1A Output 2B (Not Used)
5
Port 1A Output 3A (0-100)
6
Set amp range 0.0-10.0A = Data Range 0-100
Port 1A Output 3B (Not Used)
7
Not Used
8
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Command Value
88 (0x58)