background image

 

Section 78 

 

00-02-0618 

04-10-07 - 

5 -

 

Panel Mounting 

WARNING:  Do not install the CANdrive module near exhaust 
manifolds, turbochargers or other engine locations that might 
exceed the maximum allowable operating temperature of 185

°

(85

°

C). 

CANdrive modules are surface-mounted with four no.4 screws, fixing center dimensions as 
shown. Select screw length according to panel thickness, ensuring a maximum of 1/2 inch 
(13mm) screw depth into the CANdrive module fixing holes. 

Model CDV100F, with forward facing connector, is designed for surface-mounting inside an 
enclosed panel.  

Model CDV300F, with additional LEDs and rearward facing connector, is designed for front-of-
panel mounting: these modules require an additional 2.4” x 1.6” (60 x 40mm) cut-out for rear 
access to connector and links. The CDV300F includes a CDVG gasket (fitted into a well 
behind the rim of the case) to provide front environmental sealing to IP65. 

 

Before mounting, ensure that the final position allows access for: 

  Connection of the included wire harness. 

  Configuration of links L1 to L5 (position as shown). Alternatively, ensure that the links 

are set correctly before mounting.  See Configuration section below for full details. 

Содержание CANdrive CDV-PW-30

Страница 1: ...00 02 0618 04 10 07 Section 78 CANdrive Module Installation and Operations Manual...

Страница 2: ...uery please contact your Murphy representative for technical support Please read the following information before installing BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT A visual inspection of...

Страница 3: ...ntroduction 1 Installation Instructions 2 Configuration 2 Electrical Connection 3 Panel Mounting 5 Operation and Maintenance 6 Gage Driver Outputs 6 Indicating LEDs 6 Maintenance 7 Specifications 8 Po...

Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...es User configurable links allow for selectivity between 12 or 24 VDC systems and for all gage outputs to be selected for Murphy VDO or Datcon CANdrive is packaged in a compact surface mounted case wi...

Страница 6: ...time breakable and are not replaceable Care must therefore be taken to select the correct options before cutting links Configuration Table Link Function Link Options L1 CANbus 120 Ohm resistor Cut L1...

Страница 7: ...s are available with the connector facing forward through the front label F option e g model CDV100F or rearward through the epoxy encapsulation R option model CDV300R CANdrive electrical connection i...

Страница 8: ...AT H A series Pin 7 gives no output below 100 RPM engine speed Connect each output to the appropriate gage tachometer signal input Gage tachometer negative terminals should be common to battery negati...

Страница 9: ...facing connector is designed for surface mounting inside an enclosed panel Model CDV300F with additional LEDs and rearward facing connector is designed for front of panel mounting these modules requir...

Страница 10: ...J1939 activity can originate from ANY device on the CANbus network and may not be valid data from the engine ECU Model CDV300R has additional LEDs for indication of engine faults as transmitted from...

Страница 11: ...efore limited to the following preventative checks Check that electrical connections are secure Check that the CANdrive module is securely mounted and kept free from exposure to water or build up of e...

Страница 12: ...essure gage coolant temperature gage Link selectable for Murphy VDO or Datcon electric gages Tachometer Pulsed DC approximately 121 Hz 1500 RPM General Overall dimensions W x H x D Case 2 7x3 8x0 9 in...

Страница 13: ...Industries Inc This document including textual matter and illustrations is copyright protected by Murphy Industries Inc with all rights reserved c 2007 Murphy Industries Inc Other third party product...

Страница 14: ......

Отзывы: