background image

 

Section 78 

 

00-02-0618 

04-10-07 - 

1 -

 

General Information 

Introduction 

As part of the MurphyLink

®

 family, the 

Murphy CANdrive

 

offers a cost effective instrument 

solution for modern electronic engines. CANdrive acts as an interface between ECU 
CANbus/J1939 transmitted data and standard electric indicating gages. CANdrive and electric 
gages are an alternative solution to retrofitting of engine senders, magnetic pickups and 
associated wiring. 

CANdrive has dedicated outputs for a tachometer, oil pressure, and coolant temperature 
electric gages.  User configurable links allow for selectivity between 12 or 24 VDC systems, 
and for all gage outputs to be selected for Murphy, VDO, or Datcon. 

CANdrive is packaged in a compact, surface mounted case with epoxy encapsulation for 
maximum durability and environmental sealing. Electrical connection is via a 12-way 
automotive-type connector. 

Standard Model Options 

Stock Code 

Model / Description 

78-70-0363

 

CDV100F, 

CAN drive J1939 to electric gage interface.  1 x CAN 

status LED, connector forward

 

78-70-0364

 

CDV300R

, CANdrive J1939 to electric gage interface.  8 x 

status/fault LEDs, connector rearward.  Model CDVG sealing 
gasket included. 

78-00-0437

 

CDV-PW-30

, CANdrive power and CAN harness.  Length:  30 in. 

(0.762m).  Included with CDV100F and CDV300R

 

 

 

Содержание CANdrive CDV-PW-30

Страница 1: ...00 02 0618 04 10 07 Section 78 CANdrive Module Installation and Operations Manual...

Страница 2: ...uery please contact your Murphy representative for technical support Please read the following information before installing BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT A visual inspection of...

Страница 3: ...ntroduction 1 Installation Instructions 2 Configuration 2 Electrical Connection 3 Panel Mounting 5 Operation and Maintenance 6 Gage Driver Outputs 6 Indicating LEDs 6 Maintenance 7 Specifications 8 Po...

Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...es User configurable links allow for selectivity between 12 or 24 VDC systems and for all gage outputs to be selected for Murphy VDO or Datcon CANdrive is packaged in a compact surface mounted case wi...

Страница 6: ...time breakable and are not replaceable Care must therefore be taken to select the correct options before cutting links Configuration Table Link Function Link Options L1 CANbus 120 Ohm resistor Cut L1...

Страница 7: ...s are available with the connector facing forward through the front label F option e g model CDV100F or rearward through the epoxy encapsulation R option model CDV300R CANdrive electrical connection i...

Страница 8: ...AT H A series Pin 7 gives no output below 100 RPM engine speed Connect each output to the appropriate gage tachometer signal input Gage tachometer negative terminals should be common to battery negati...

Страница 9: ...facing connector is designed for surface mounting inside an enclosed panel Model CDV300F with additional LEDs and rearward facing connector is designed for front of panel mounting these modules requir...

Страница 10: ...J1939 activity can originate from ANY device on the CANbus network and may not be valid data from the engine ECU Model CDV300R has additional LEDs for indication of engine faults as transmitted from...

Страница 11: ...efore limited to the following preventative checks Check that electrical connections are secure Check that the CANdrive module is securely mounted and kept free from exposure to water or build up of e...

Страница 12: ...essure gage coolant temperature gage Link selectable for Murphy VDO or Datcon electric gages Tachometer Pulsed DC approximately 121 Hz 1500 RPM General Overall dimensions W x H x D Case 2 7x3 8x0 9 in...

Страница 13: ...Industries Inc This document including textual matter and illustrations is copyright protected by Murphy Industries Inc with all rights reserved c 2007 Murphy Industries Inc Other third party product...

Страница 14: ......

Отзывы: