![Murdock M-OBR4-GRC Series Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/murdock/m-obr4-grc-series/m-obr4-grc-series_installation-and-maintenance-instructions-manual_1857638006.webp)
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Bottle Filler Installation
M-OBR4-GRC
Page 6 of 16
New: 12
/19/17
7020-963-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
OUTDOOR BOTTLE FILLERS
1
Position Bottle Filler Box in the center of the Mounting Plate
opening and secure with #10-32 x 1/4" Phillips Head Screws.
Note: Cutoff 2-1/2" of material from the tailpiece. See Detail A.
2
Position Bottle Filler Panel and center to Mounting Plate
and secure with #10-32 x 1/2" Stainless Steel Flat Head
Center Reject Hex Screw.
3
With Bottle Filler Panel installed, open Bottle Filler. Remove
the #10-32 x 3/4" Flat Head Center Reject Screws and
swing open Bottle Filler.
1
2
3
2
4
3
1
2
3
4
3
1
2
3
2
1
2
5
Detail A
2
1
2
"
Cutoff Material
Finished Wall
Mounting Plate
Bottle Filler Box
1
2
3
10-32 x 1/4" Screws
1-1/4" OD Tailpiece
4
5
Finished Wall
Mounting Plate
Bottle Filler Panel
1
2
3
10-32 x 1/2" Screws
4
Bottle Filler Panel
Bottle Filler
#10-32 x 3/4" Screws
1
2
3