background image

 

A181CUSP SERIES FULLY RECESSED ADA FOUNTAIN & CUSPIDOR

NOTICE

A dielectric coupling must be used to connect the drinking fountains to the water supply . A nonmetallic 
coupler is furnished with this drinking fountain to meet this requirement.

ROUGHING-IN AND DIMENSIONAL DRAWING

Prior to roughing consult with local, state, and federal codes for proper mounting height. 

NOTES: 

Dimensions indicated are for ADA frontal approach installation. For Child ADA-ABA compliant parallel 
approach installation, decrease height of installation for spout to be 30” maximum above finished floor. 
Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, 
state, and local codes. 

 Adjust vertical dimensions as required to comply with federal, state, and local codes. 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A181-CUSP

Page 2 of 9

02/26/16

7020-003-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

1-1/4" OD SLIP

JOINT WASTE
CONNECTION

 GENERAL NOTES:
 1. ALL DIMENSIONS ARE IN INCHES.

*2. DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL

DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE & LOCAL CODES.

 3. STOP VALVE NOT PROVIDED.

17"

WALL

OPENING

12"

WALL

OPENING

22" - 40"

1

3
8

"

6"

25

3
8

"

2"

6"

(4) Ø

1

8

" MTG

HOLES

ACCESS

PANEL

72" MIN

WALL

OPENING

*33"

30"

WALL

OPENING

9

1
2

"

27"

WALL

OPENING

15" MIN

15" MIN

17" MIN

1

3
8

"

30

3
4

"

Содержание A18040000-CUSP

Страница 1: ...l constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each...

Страница 2: ...ocal codes Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 2 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 74...

Страница 3: ...nts are assembled to the fixture that are not approved by Acorn Engineering Company 5 Fixtures operates within water pressure range of 20 to 105 psig Acorn Engineering Company will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig A pressure regulator must be furnished by others on supply line if inlet pressure is greater tha...

Страница 4: ...ed to pass through the tabs on both units and into the tabs of the lower frame bracket containing the captive nuts Tighten the screws to pull the Fountain Cuspidor flush with the wall 7 Install water supply and drain as required per Figure A rough in dimensions 8 Thoroughly flush the supply lines connect water supply to the Cuspidor 9 Make up 1 1 4 OD P Trap waste connection UPPER MOUNTING BRACKET...

Страница 5: ...r to locate your local representative is 1 800 591 9360 CLEANING MAINTENANCE GUIDE 1 Periodically remove access panels and clean out in line strainer 2 Do NOT use harsh chemicals abrasive or petroleum based cleaners Use of these will void the Acorn warranty 3 Exterior panels can be cleaned using mild household detergents or warm soapy water Extra care must be used cleaning chrome plated items and ...

Страница 6: ...h in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I ...

Страница 7: ... L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 7 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 2 4 3 5 6 9 10 20 11 12 13 14 15 16 19 22 23 24 18 17 8 7 1 21 ...

Страница 8: ...GE 0 5 GPM 24 7000 050 001 VALVE ASSEMBLY 1 ITEM PART NUMBER DESCRIPTION 7000 012 001 STAINLESS STEEL BUBBLER ASSEMBLY 7000 099 002 LOW FLOW FLEX BUBBLER GRAY 2 7035 128 199 UPPER MOUNTING BRACKET 3 N A N A 4 N A N A 5 N A N A 6 N A N A 7 N A N A 8 N A N A 9 4926 055 001 GRID STRAINER w CLOSE ELL ASSY 10 0316 020 000 CAPTIVE NUT 11 0331 004 000 10 FLAT WASHER 12 0321 011 000 10 STAR WASHER 13 0116...

Страница 9: ...ORT ADA 15 0279 002 000 8 32 SOCKET CAP BUTTON HD SCREW 3 4 LG 16 0322 001 000 8 PLATED STAR LOCK WASHER EXTERNAL 17 7002 125 001 WELDED PUSHBUTTON AIR TROL VALVE ASSY 18 7002 125 002 PUSHBUTTON ASSY AIR VALVE 19 7035 306 001 BRACKET FRAME LWR FTN ONLY ADA 20 7000 415 000 SELF RETAINING J NUT 21 N A N A 22 N A N A 23 N A N A 24 N A N A A181 CUSP Page 9 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 ...