background image

Installation Instructions                                                           

 

1  | 

P a g e  

 

v 1 . 0   ( 0 9 / 2 0 1 9 )        

 

WITNER LED WALL BRACKET with Sensor 

SKU# 240812 

Rated Voltage 220-240V~ 50Hz 

 
Thank  you  for  purchasing  this  quality  Lucci  product. To  ensure  correct  function  and  safety,  please  read  and  follow  all 
instructions carefully before assembly, installation and use of this product. Please keep instructions for future reference. 

Warranty 

 

This luminaire is covered by a 3 year warranty. The warranty is from date of purchase, not the date of installation.   

 

If the luminaire is not assembled and installed by a licensed electrician the warranty will be void. 

 

Please retain proof of purchase and evidence of installation by a licensed electrician.   

 

Warranty will be void if there is any damage due to improper usage or modification to the luminaire. 

 

Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void warranty. 

 

Installation requirements 

 

Must be assembled and installed by a licensed electrician. 

 

All wiring and installation of the luminaire must adhere to latest local and national wiring rules.   
eg. AS/NZS 3000 Electrical installations.   

 

This luminaire is not suitable for use with dimmer switches and should not be used on a circuit which has a dimmer.   

 

Select a suitable location for installation: 

This luminaire is protected against water penetration to IP54 standards, which is splashing from every 
direction. This must be maintained during installation. 

It is suitable for indoor or outdoor use. 

The mounting point must support 2 times the weight of the luminaire.   

 

Take care not to pull any electrical wires during unpacking as this may damage the connection.   

 

Lay out all the components on a smooth surface and make sure there are no components missing before assembling. 
If parts are missing, return the complete product to the place of purchase for inspection or replacement. 

 

Check whether the luminaire has been damaged during transport. Do not operate/install any product which appears 
damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. 

 

Installation directions 

 
Remove all packaging material from the product and be careful not to throw away accessories that may be hidden 
within the packaging material. 

 

1. 

Switch off the power before commencing the installation. (Fig.1) 

2. 

Remove the mounting bracket by loosening the screws from both sides using the Allen key provided. (Fig.2) 

3. 

Adjust the colour temperature according to your needs by using the switch A. (Fig.3) 

4. 

Install  the  mounting  bracket  on  the  wall  by  using  appropriately  sized  mounting  screws  and  anchors.  Ensure  the 
screws and anchors used are suitable for mounting surface and the surrounding environment. (Fig.4, 5) 

NOTE: It is recommended that a non-corrosive bead of silicone be applied before installation onto the wall 
ensuring that no water can run down into the cabling. 

5. 

Connect the mains supply wire to the luminaire using the terminal block provided. Ensure that the wires are secure 
and no bare wires are exposed. (Fig.6) 

 

 

Содержание 240812

Страница 1: ...maintained during installation It is suitable for indoor or outdoor use The mounting point must support 2 times the weight of the luminaire Take care not to pull any electrical wires during unpacking as this may damage the connection Lay out all the components on a smooth surface and make sure there are no components missing before assembling If parts are missing return the complete product to the...

Страница 2: ...tening the screws on the both sides Fig 7 NOTE Check and ensure the two screws are tightened 7 Adjust the PIR sensor according to your need Fig 8 Refer to the PIR sensor information section for more information 8 Make any final adjustments to the luminaire and check that all parts are secured tightly before turning the power on Fig 9 NOTE When adjusting the height of the head do not adjust more th...

Страница 3: ...er at different temperatures PIR sensors are more sensitive in cold weather than warm weather The sensor has better sensitivity with movement across the detection area The sensor has reduced sensitivity with movement towards and away from the detection area If movement is made walking directly towards or away from the sensor and not across the apparent detection range will be substantially reduced...

Страница 4: ...um duration for manual mode is 8 hours Then the luminaire will be back into the sensor mode automatically after the maximum duration 2 The manual mode can be stopped by turning the luminaire OFF then wait for 1 minute to switch the luminaire on again Wall switch action OFF Wait for 1 minute ON The luminaire will be back into the sensor mode Safety tips Always ensure the power is OFF and the lumina...

Отзывы: