background image

PUSH-IN FITTING INSTALLATION

NOTE: FITTINGS AND TUBE SHOULD BE KEPT 
CLEAN, BAGGED AND UNDAMAGED PRIOR TO 
INSTALLATION.

2. Pull on the fitted tubing to ensure it is secure. Tube 

should not come free from the fitting. Water test the 
connection assembly prior to leaving the site to ensure 
there are no leaks.

DISCONNECTING THE TUBE:

To disconnect the tube from the fitting ensure that the 
water line is depressurized. Push collet square towards 
the push-in fitting body and hold. While holding the collet 
in, pull on the PE tubing to remove from the push-in fitting. 

TO CUT TUBE:

Cut to fit length of 1/4” PE tubing and remove any burrs 
or sharp edges. Ensure that the outside diameter is free 
from score marks. Tube ends should be square.

INSERTING THE TUBE:

1.  Firmly and fully insert the tubing end into the push-in 

fitting up to the tube stop located approximately ½” 
deep.

COLLET

COLLET

O-RING

O-RING

TUBE STOP

COLLET

COLLET

COLLET

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A181-CUSP

Page 6 of 9

02/26/16

7020-003-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Содержание A18040000-CUSP

Страница 1: ...l constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each...

Страница 2: ...ocal codes Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 2 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 74...

Страница 3: ...nts are assembled to the fixture that are not approved by Acorn Engineering Company 5 Fixtures operates within water pressure range of 20 to 105 psig Acorn Engineering Company will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig A pressure regulator must be furnished by others on supply line if inlet pressure is greater tha...

Страница 4: ...ed to pass through the tabs on both units and into the tabs of the lower frame bracket containing the captive nuts Tighten the screws to pull the Fountain Cuspidor flush with the wall 7 Install water supply and drain as required per Figure A rough in dimensions 8 Thoroughly flush the supply lines connect water supply to the Cuspidor 9 Make up 1 1 4 OD P Trap waste connection UPPER MOUNTING BRACKET...

Страница 5: ...r to locate your local representative is 1 800 591 9360 CLEANING MAINTENANCE GUIDE 1 Periodically remove access panels and clean out in line strainer 2 Do NOT use harsh chemicals abrasive or petroleum based cleaners Use of these will void the Acorn warranty 3 Exterior panels can be cleaned using mild household detergents or warm soapy water Extra care must be used cleaning chrome plated items and ...

Страница 6: ...h in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I ...

Страница 7: ... L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 7 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 2 4 3 5 6 9 10 20 11 12 13 14 15 16 19 22 23 24 18 17 8 7 1 21 ...

Страница 8: ...GE 0 5 GPM 24 7000 050 001 VALVE ASSEMBLY 1 ITEM PART NUMBER DESCRIPTION 7000 012 001 STAINLESS STEEL BUBBLER ASSEMBLY 7000 099 002 LOW FLOW FLEX BUBBLER GRAY 2 7035 128 199 UPPER MOUNTING BRACKET 3 N A N A 4 N A N A 5 N A N A 6 N A N A 7 N A N A 8 N A N A 9 4926 055 001 GRID STRAINER w CLOSE ELL ASSY 10 0316 020 000 CAPTIVE NUT 11 0331 004 000 10 FLAT WASHER 12 0321 011 000 10 STAR WASHER 13 0116...

Страница 9: ...ORT ADA 15 0279 002 000 8 32 SOCKET CAP BUTTON HD SCREW 3 4 LG 16 0322 001 000 8 PLATED STAR LOCK WASHER EXTERNAL 17 7002 125 001 WELDED PUSHBUTTON AIR TROL VALVE ASSY 18 7002 125 002 PUSHBUTTON ASSY AIR VALVE 19 7035 306 001 BRACKET FRAME LWR FTN ONLY ADA 20 7000 415 000 SELF RETAINING J NUT 21 N A N A 22 N A N A 23 N A N A 24 N A N A A181 CUSP Page 9 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 ...

Отзывы: