I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
7020-904-001
RE-PIPING FROM NON-PRESSURIZED
TO PRESSURIZED (FOR -GF & -BF ONLY)
To re-pipe a single non-pressurized unit to pressurized, you
will have to move the water supply Tubing around, with
“
NO
” additional Tubing needed. Before performing this task,
you
MUST SHUT OFF THE WATER SUPPLY
, and
disconnect all supply connections.
STEP 3:
From the outlet of the Cartridge assembly, connect to
the Bubbler.
STEP 1:
Starting with the supply line coming from the wall,
connect to the inlet of the Evaporator assembly.
STEP 2:
From the outlet of the Evaporator assembly, connect to
the inlet of the Cartridge assembly.
Wall Supply Connection
17" Water Supply Tubing
Evaporator Inlet Connection
13" Water Supply Tubing
Bubbler Connection
Cartridge Assembly
Outlet Connection
Cartridge Assembly
Inlet Connection
Evaporator Outlet Connection
TO -BF OR -GF
Add
1
4
" O.D. Tee for -BF or -GF