A171.8
Revised:
09/07/18
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
7020-904-001
14. For optimum performance, the fixture is to operate within the ambient temperature range of 41°F
(5°C) to 111°F (44°C).
1. Mount Hanger Bracket to wall horizontally level as shown in Roughing-In and Dimensional Drawing.
Note: Adjust height of Bracket if Bubbler outlet height is required to vary from that shown/indicated
.Hanger Bracket MUST be securely anchored to wall with fasteners sufficient to support 3 times the
weight of Water Cooler. If wall cannot provide adequate support, order and install optional fixture
support carrier.
4. Recheck all water and drain connections with water flowing through system.
5. Thoroughly flush the 3/8” O.D. supply line and then connect Water Cooler to water supply Angle
Stop Valve (by others) with supplied 3/8” O.D. copper Tubing.
2. Remove the Bottom Cover from the Water Cooler and set aside in a safe place. Place the Screws
in a secure location for re-use in later stages of installation.
5. With power still NOT connected, carefully rotate Cooling Fan manually to insure proper clearance
and free Fan action.
3. Hang the Water Cooler on the Hanger Bracket, ensuring the Bracket Tabs engage AND seat in the
slots in the back of the Water Cooler. Verify Water Cooler is level, left to right AND front to back from
bottom of unit. NOTE: The Bubbler stream may be adversely affected if unit is not square and level.
Bottom of unit and Louvers should be used as reference to verify unit is square and plumb.
INSTALLATION:
START UP:
6. Make up 1-1/4” O.D. P-Trap (by others) waste connection.
1. Before connecting Power Supply and assembling Bottom Cover to Water Cooler, but after
thoroughly flushing the supply line and connecting it to the fixture, turn on building water supply and
check all connections for leaks.
2. Air within the Water Cooler system or the structure supply piping will cause an irregular Bubbler
outlet stream until purged out by incoming water. Covering the Bubbler with a clean cup (or similar
object) is recommended when first activating Water Cooler to prevent excessive splashing. Depress
the Pushbutton until steady water stream is achieved.
15. If the Power Supply Cord is damaged, it may only be replaced by authorized qualified persons.
4. Anchor Water Cooler to wall at other mounting points in Base. Shim lower rear mounting points to
level unit, if necessary.
13.
609.10.1 Mechanical Devices.
Where listed mechanical devices are used, the manufacturer’s
specifications as to location and method of installation shall be followed.
3. If water flow requires adjustment, insert a slotted narrow blade Screwdriver through the hole
centered on the Pushbutton to the Flow Regulator. Turning clockwise will increase flow and turning
counterclockwise will decrease flow.
6. Plug Water Cooler into Electrical Outlet and make sure unit begins to function.
7. Assemble Bottom Cover to Water Cooler with Screws furnished.