background image

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 WATER COOLERS

 

7020-904-001

A171.8 Series

Barrier Free, Wall Mounted Water Cooler 

 

A171108F / A171408F / A171108S / A171408S

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

 

 

 

 

 

Date: 09/07/18

COMPLIES 

WITH

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

LIMITED WARRANTY - UNITED STATES & CANADA

LIMITED EXPORT WARRANTY - 

One year on parts only. 

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above.

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

Содержание A171 Series

Страница 1: ...he compressor and hermetically sealed refrigeration system including cooling coil assembly when part of the hermetically sealed refrigeration system to be free from defects in material and workmanship under normal use for an additional four 4 years from the end of the one 1 year period described above This warranty does not cover installation or labor charges and does not apply to materials which ...

Страница 2: ...r away from it Every attempt should be made to prevent this kind of grounding from generating electrical feedback into the Water Cooler creating electrolysis Electrolysis will cause a metallic taste or cause water metal content to increase NOTICE ROUGHING IN AND DIMENSIONAL DRAWING NOTES Dimensions indicated are for ADA frontal approach installation Adjust vertical dimension as required to comply ...

Страница 3: ...older Tubing inserted into the Coupler as damage to the O Ring may result 1 Waste P Trap Water Supply Service Angle Stop Valve and 2 x 4 Electrical Plug In Receptacle to be supplied by others in accordance with local codes A metallic P Trap by others must be used for the Drain connection 10 Fixture is to operate within a water pressure range of 25 PSIG 172 kPa to 105 PSIG 724 kPa Warranty is void ...

Страница 4: ... the slots in the back of the Water Cooler Verify Water Cooler is level left to right AND front to back from bottom of unit NOTE The Bubbler stream may be adversely affected if unit is not square and level Bottom of unit and Louvers should be used as reference to verify unit is square and plumb INSTALLATION START UP 6 Make up 1 1 4 O D P Trap by others waste connection 1 Before connecting Power Su...

Страница 5: ...0 000 TUBING LLDPE BLUE 1 4 OD 5 3 7012 311 000 WF1 FILTER 1500 GALLON 1 ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE BLUE 1 4 OD 5 NON PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH FILTER WITHOUT GF BF OPTIONS 1 Starting from the wall connection connect to the inlet of the Water Filter 2 From the outlet of the Water Filte...

Страница 6: ... N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS 7020 904 001 PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH GF BF OPTIONS ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE BLUE 1 4 OD 5 17 Water Supply Tubing 13 Water Supply Tubing 1 2 To BF Bott...

Страница 7: ...o move the water supply Tubing around with NO additional Tubing needed Before performing this task you MUST SHUT OFF THE WATER SUPPLY and disconnect all supply connections STEP 3 From the outlet of the Cartridge assembly connect to the Bubbler STEP 1 Starting with the supply line coming from the wall connect to the inlet of the Evaporator assembly STEP 2 From the outlet of the Evaporator assembly ...

Страница 8: ...r Thermostat The water temperature can be adjusted using a slotted Screwdriver and turning clockwise to make colder and counterclockwise to make warmer c Bubbler Stream Bubbler can be rotated slightly to direct the stream backwards or forwards Adjust the stream to minimize splashing Splashing may occur from Bubbler stream if the unit is not level Shim lower mounting points if necessary to level Wa...

Страница 9: ...tore electrical power if no damage is found 5 Noisy Operation a Check to make sure the Fan Blade is rotating freely b Make sure the Water Cooler is correctly mounted to the wall Absence of the two lower mounting bolts may cause excess noise and vibration c Check the Compressor mounting to make sure the Pins and Clips are not rattling If the Compressor appears to be noisy internally it must be repl...

Страница 10: ...es and pull firmly to remove the Button Remove Cartridge Retaining Nut Remove and replace Cartridge When replacing Cartridge be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body Note Use the Universal Maintenance Tool to perform the following NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW 1 Strainer Plug must be removed before Cartridge replacement...

Страница 11: ...uld not come free from the Fitting Water test the Connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the Fitting ensure that the water line is depressurized Push Collet square towards the Push In Fitting Body and hold While holding the Collet in pull on the plastic PE Tubing to remove from the Push In Fitting TO CUT TUBE Cu...

Страница 12: ...O N S WATER COOLERS 7020 904 001 Standard A171 8 series refrigerated ADA Water Cooler shown All 1 4 O D Plastic Tubing 24 must be insulated with 25 foam insulation NOTE See next page for table of part numbers corresponding to drawing above WATER COOLER PARTS BREAKDOWN Universal Maintenance Tool Pushbutton Removal Removal of P E Tubing from Cartridge Retaining Nut Strainer Plug Push in Fittings 27 ...

Страница 13: ... 0124 032 000 8 x3 4 LG PHIL FLAT HD SELF TAPPING SCREW 4 7000 006 000 FLAT DRAIN GASKET 5 7003 180 000 DRAIN TAILPIECE 6 7003 003 199 BACK PANEL 7 7003 007 199 SUPPORT STRUT 8 7003 250 000 COLD CONTROL 7003 210 020 APRON ASSEMBLY GRANITE 7003 211 002 APRON ASSEMBY STAINLESS STEEL 10 7003 095 001 VALVE ASSEMBLY 11 7003 099 000 PUSHBUTTON 7003 004 020 COVER GRANITE 7003 035 299 COVER STAINLESS STEE...