Common System Problems
The following table offers suggestions for resolving some common system
problems that the operator may experience from the radio system. If problems
persist, contact the factory for further assistance.
Problem
System Checks
Unit is inoperative
1. Check for proper DC voltage at the power
connector.
2. Momentarily remove and reapply power.
No Carrier Detect
at remote units or
intermittent
1. Check for secure interface connections at the
transceiver.
2. Check antenna, connectors, and reflective
power.
3. If remote unit is in synchronization but
performance is poor, it may indicate antenna
problems. Check for properly aligned antenna
headings.
4. Verify proper system parameter values.
Interference is
suspected
1. Verify that the system has a unique network
address. Nearby systems with same address
will cause interference problems.
2. If Omni-directional antennas are used with the
remote units, consider using a directional type
instead. This will often limit interference to and
from other stations.
3. Check RSSI value at the remote. A low value
would correspond to weak signal strength.
Copyright © Murata Manufacturing Co., Ltd. All Rights Reserved. 2012