Set ARQ Mode
This command sets ARQ mode when set to 0 which is the default. In this
mode the radio will resend an unsuccessful transmission until either
successful or
packet attempt limit
attempts have been made. When set to 1
selects redundant transmit mode that will send every transmission
packet
attempt limit
times regardless of success or failure of any given attempt.
When redundant transmit mode is used, receiving radios will discard all
subsequent retransmissions once the transmission has been successfully
received. Thus the receiving host will receive just one copy of the
transmission.
Status Commands
These commands deal with general interface aspects of the operation of the
HopNet.
Command
Description
zb[?|0|1]
Banner Display Disable
0 = disabled
1 = enabled (default)
zc[?|0|1|2]
Set Escape Sequence Mode
0 = disabled
1 = once after reset (default)
2 = unlimited times
zh?
Read factory serial number high byte.
zm?
Read factory serial number middle byte.
zl?
Read factory serial number low byte.
zp[?|0-5]
base only)
Set the duty cycle at which the modem will wake up to send
and receive data. Duty cycle equals 1/2
N
where the
argument of the command equals N.
zq[?|0|1]
(remote only)
Low Power Acquisition Mode Enable
0 = Disabled (default)
1 = Enabled
z>
Exit Modem Control Mode
Copyright © Murata Manufacturing Co., Ltd. All Rights Reserved. 2012
HN-210D/X, HN-214D/X Rev. 2.0 01/13/17
50 of 64