You can also optionally run the tunnel curtain under pressure control. In that event, the percent open
settings become minimum settings. Then, once the side vents are at 100%, if pressure requires, the Master
will open the tunnel curtain to maintain the pressure setting.
6.4
Circulation Fan
CIRCULATION FAN #01
Sensors Dif
From Time
3.0
00:00
To Time
From Level
To Level
00:00
1
10
The circulation fans will mix the air inside the house and control temperature differentials between
different parts of the house.
•
Sensors Dif: the circulation fan will start if the difference between temperatures in different parts
of the house will be higher than the set differential. The sensors that participate in this differential
can be divided in to 3 groups:
o
If no sensors are set for circulation fans in temp definition, the current defined sensors will
control this operation. If for example the house is in tunnel mode, the tunnel sensors will
control the circulation fans. If there will be difference higher then 3 (like the example
above) between 2 sensors the circulation fans will begin to operate.
o
If one sensor is defined for the circulation fans, the difference between this sensor and
the average will control the circulation fans.
o
If more than one sensor is defined for the circulation fans, when the difference increase
between any 2 sensors, the circulation fans will begin operation.
•
From Time: from what time to start the application.
•
To Time: to what time operate this application.
•
From Level: from what level to operate this application.
•
To Level: up to what level operate this application.
If any of the four definitions above is set on 0, the circulation fan operates at any time or level according
to the differential.
6.5
Cool Pad
Cool Pad #01
#
From
To
Diff
%RH
On
Off
1
2
08:00
10:00
20:00
18:00
3.0
5.0
85
75
30
60
90
60
The cooling table provides settings for the evaporative cool pad system. There are up to 5 fragments
allowing precise control over this system. Several fragments can be selected for the same day.
•
FROM: (HH:MM) Start time.
•
TO: (HH:MM) End time.