![Munters Element Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/munters/element/element_manual-for-use-and-maintenance_1856884026.webp)
© Munters AB, 2018
26
Figure 11 key
1
Element low voltage ports
4
Variable fan device
2
Digital sensors (Two devices can be wired to
one COM port)
5
Fans
3
Variable heat device
Figure 12 key
1
Element low voltage ports
2
Water meter
3
Auxiliary alarms
NOTE
Figure 11 and Figure 12 are examples. Actual installations can differ.
5.2.4.2
Configuring the Analog Output Devices
Wire the analog output devices to the Element as shown in Figure 11.
1.
Go to System > Installation > Analog Out.
2. Scroll to each analog output.
3. From the drop down list, select the device wired to that relay.
o
Element automatically assigns the device a number, according to the device type. The
number of devices supports varies according to the device type.
Heater: 6
Fan: 8
Stir Fan:1
o
You can edit the number, but any assigned number must be different from an existing
number of that device type (for example, you cannot assign two relays to be Heater
#2).
o
Similar relay, analog output, and TRIAC devices must have different numbers.
o
If no relay is available (for example, if you try to define three relays as curtains), an
error message appears.