Step 3C
At the middle of the long side of the insulation
stop,12,7 mm down from the top, drill or punch a 6,35
mm dia. hole on each side of the insulation stop.
See
Figure 3C.
Step 3D
Install (1) Retaining Clip [C] on each end of the
fi berglass rod. The Retaining Clip should be 38,1 mm
from the end of the rod. Then insert the end of the
rod through the new hole in the insulation stop from
the inside out. Insert the other end of the rod through
the hole in the other side of the insulation stop. Install
the remaining Retaining Clip [C] on each end of the
fi berglass rod, so that the insulation stop is between 2
of the clips.
See Figure 3D.