Munters Aerotech VX Series Скачать руководство пользователя страница 14

© Munters Corporation, January 2020

14

QM1105r3

Winterizing

6.

 

In most climates, it is probable that the ventilation system will never need to operate at a total capacity during 
the colder winter months. Consequently, it is advisable to “winterize” those fans which will not be used in cold 
weather to avoid unnecessary heat loss and condensation.

To winterize, turn fan control “off”. Install the insulated closure panel over the fan intake. If you don’t have an 

insulated closure panel, a piece of rigid insulation material can be used. Remember the insulation panel must 
be removed before warmer weather returns.

NOTE:

  At least one single speed fan should be left uncovered and with power available to provide air     

      

 

movement in the event of variable speed control difficulties.

6.1 Winterizing

6.2 Winter Weather Protection

To prevent cone or fan damage from snow or ice sliding off building roof, weather protection must be 
provided. A weather shelter may be constructed to cover the entire fan, 

See Figure 8,

 or snow guards may be 

placed on the roof, 

See Figure 9.

Building
Wall

Provide Weather 
Shelter Over Fans

6" Min.

Fan with
Discharge Cone

Figure 8

Note:

 

Snow guards are designed to prevent sudden, dangerous snow 

and ice slides when attached to the building roof according to 
manufacturers recommendations. The supplier listing above is given 
as a reference only. Munters does not endorse any specific snow 
guard product and no performance warranty is implied.

 

Munters Product and System 

Warranties do not cover cone or fan 

damage from external sources.

IMPORTANT

!

Snojax, Inc. 

800-766-5291 

717-697-2452 

www.snojax.com

Polar Blox 

800-298-4328 

814 629-9090 

www.polarblox.com

LM Curbs 

800-284-1412 

903 759-3598 

www.lmcurbs.com

Alpine Snow Guards 

888-766-4273 

888-766-9994 

www.alpinesnowguards.com

*Snow Guard Suppliers

 

Company Name 

Phone No. 

Fax No. 

Web Site

Snow Guards located 
per manufacturers 
recommendations*

Ceiling

Figure 9

Fan with
Discharge 
Cone

Содержание Aerotech VX Series

Страница 1: ...1 Munters Corporation July 2020 QM1105r3 Instruction Manual VX Fans Direct Drive Models VX14F1 VX16F1 VX18F1 VX24F1 VX24F3 VX26F1 VX26F3 Aerotech VX Fan Direct Drive 14 26 Fans VX26 VX14 VX24 ...

Страница 2: ... Please read all instructions carefully before beginning installation Warranty For Warranty claims information see the Warranty Claims and Return Policy form QM1021 available from the Munters Corporation office at 1 800 227 2376 or by e mail at aghort info munters com Conditions and Limitations Products and Systems involved in a warranty claim under the Warranty Claims and Return Policy shall have...

Страница 3: ...List 4 1 2 Fan Dimensions 5 2 Installation Instructions 6 8 2 1 Install 6 2 2 PT Style Shutter 7 2 3 PZ Style Shutter 8 3 Electrical Wiring 9 4 Operation 11 5 Maintenance 13 6 Winterizing 14 6 1 Winterizing 14 6 2 Winter Weather Protection 14 7 Troubleshooting 15 8 Exploded View and Parts List 16 17 ...

Страница 4: ... Fans ID Qty Cat No Description A 12 KS2105 14 x 1 5 Lag Screw SS Before beginning installation check the overall condition of the equipment Remove packing materials and examine all components for signs of shipping damage Any shipping damage is the customer s responsibility and should be reported immediately to your freight carrier Fan is shipped complete with all accessories ...

Страница 5: ...C Phase 1 or 3 3 Phase fans only available for VX24 VX26 FAN DIA NO OF BLADES A B C D E F G Dia O D WALL OPENING I D framed 14 7 45 16 12 205 8 173 8 165 8 7 145 8 171 2 W 171 2 H 16 4 43 4 16 251 2 221 4 183 4 51 2 1611 16 221 2 W 221 2 H 18 5 43 4 16 251 2 221 4 183 4 51 2 1811 16 221 2 W 221 2 H 24 4 53 4 20 311 2 281 4 193 4 51 2 2411 16 281 2 W 281 2 H 26 3 51 2 22 33 293 4 181 8 107 16 27 30...

Страница 6: ...he previous page See Figure 1 Wall Opening See Chart on previous page Step 2 Insert fan into framed opening from inside and fasten in place using 8 Lag Screws A Flash and caulk around opening See Figure 2 2x4 Framing Lag Screw A VX Fan Figure 2 OUTSIDE INSIDE Note Outlet of fan comes unguarded it is recommended that a Munters Discharge Cone with Guard a Fan Hood with Guard or a guard by others is ...

Страница 7: ...Z PV Style Shutter Step 3 Insert PZ PV shutter into back of fan See Figure 3A Fasten shutter in place by rotating the side and top shutter clips over the shutter flanges See Figure 3B Installation is now complete proceed to electrical wiring section PZ PV Shutter Figure 3A Figure 3B ...

Страница 8: ... 4 minimum and bottom requires 2 minimum Step 5 Insert PT shutter into back of fan See Figure 5A Fasten shutter in place by rotating the side and top shutter clips over the shutter flanges See Figure 5B Installation is now complete proceed to electrical wiring section 2 Minimum Framing for fan Bottom Wall Opening See Chart on Page 5 Wall Framing 4 Minimum Framing for Fan Top and Sides Wall Framing...

Страница 9: ...be used See Figure 6A See form QM1400 for proper size Three Phase Fans motor overload protection should be provided for each fan A three pole motor starter or slow blow motor fuses must be used See Figure 6B If a frequency drive inverter is used confirm that motors are rated for inverter duty at the voltage used Shielded power cable between frequency drive and each motor is highly recommended Inst...

Страница 10: ...mum operating frequency of 30 Hz 3 Will require three pole contractors with overload protection by others As the power cable exits the back of motor form a drip loop and then run power cable down along leg of motor mount and Zip tie the cable to leg to prevent cable from getting tangled See Figure 7 Then run the cable out the drain hole to the circuit breaker or control panel Continued on next pag...

Страница 11: ... 151 750 151 150 640 142 640 142 760 152 760 152 200 660 143 670 144 780 153 790 153 300 710 145 720 146 820 154 820 154 400 760 148 780 149 860 156 870 156 500 810 151 840 153 910 158 930 160 600 840 153 880 155 950 161 980 162 800 940 158 980 160 1030 164 1070 166 1000 1030 163 1070 165 1120 168 1180 170 1200 1130 168 1210 173 1210 173 1280 177 1600 1370 182 1480 197 1400 186 1500 205 1950 1640 ...

Страница 12: ... 560 150 1750 500 143 520 144 560 150 600 153 2000 530 145 550 147 580 152 630 157 2250 560 148 590 151 610 154 670 160 2500 580 150 620 153 630 157 690 163 2750 610 152 660 156 660 159 720 166 3000 640 155 690 160 680 162 740 168 3500 690 160 760 167 730 167 790 172 4000 750 166 820 172 790 172 860 179 4500 820 172 900 183 850 178 940 191 5000 890 181 990 202 920 187 1020 210 5500 970 195 1060 23...

Страница 13: ...UTTER Carefully clean dust from shutter blades and frame so that shutter opens and closes freely A brush or cloth should be used GUARD Clean any dust or feathers from fan guards using a brush Dirty guards can reduce airflow 3 CHECK FASTENERS For safety all fasteners should be inspected 1 month after initial operation and yearly thereafter Tighten any loose connections 4 INSPECT FAN CONTROL With po...

Страница 14: ... off building roof weather protection must be provided A weather shelter may be constructed to cover the entire fan See Figure 8 or snow guards may be placed on the roof See Figure 9 Building Wall Provide Weather Shelter Over Fans 6 Min Fan with Discharge Cone Figure 8 Note Snow guards are designed to prevent sudden dangerous snow and ice slides when attached to the building roof according to manu...

Страница 15: ... Frequency drive improperly adjusted 1 Motor loose on mount 2 Propeller damaged 3 Motor shaft bent 1 Set to a lower temperature 2 Replace fuse or reset breaker 3 Realign motor in fan housing 4 Repair or replace control 5 Repair or replace motor 1 See Operation Step 2 for adjustment guidelines 2 Unjam and clean shutter 3 Clean guard 1 Sand fan housing to remove high spot 2 Repair or replace motor o...

Страница 16: ... Munters Corporation January 2020 16 QM1105r3 Exploded View 8 ...

Страница 17: ... PVC Coated 1 FH1009 16 18 Fan Motor Mount PVC Coated 1 FH1010 24 Fan Motor Mount PVC Coated 1 FH2526 26 Fan Motor Mount PVC Coated 1 5 FM1010 14 DD Motor HP 1625 RPM 48 Fr 1 ph 115 230V 1 FM1043 16 DD Motor HP 1625 RPM 48 Fr 1 ph 115 230V 1 FM1009 18 DD Motor HP 1625 RPM 48 Fr 1 ph 115 230V 1 FM1108 24 26 DD Motor HP 1075 RPM 48 Fr 1 ph 115 230V 1 FM1074 24 26 DD Motor HP 1140 RPM 48 Fr 3 ph 230 ...

Страница 18: ...235 Italy Munters Italy S p A Chiusavecchia Phone 39 0183 52 11 Japan Munters K K Phone 81 3 5970 0021 Korea Munters Korea Co Ltd Phone 82 2 761 8701 Mexico Munters Mexico Phone 52 818 262 54 00 Russia Munters AB Phone 7 812 448 5740 Singapore Munters Pte Ltd Phone 65 744 6828 South Africa and Sub Sahara Countries Munters Pty Ltd Phone 27 11 997 2000 Spain Munters Spain S A Phone 34 91 640 09 02 S...

Отзывы: