5

Roof beam

Ceiling

Fig.4-7

Fig.4-8

FOR ORIGINAL CONCRETE BRICKS

Install the hanging hook with expansible bolt into the

concrete deep to 45~50mm to prevent loose.

Fig.4-10

 

 

 

   

 

 

   

 

 

 

   

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

2

2

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

Base

Base

1

1

2

2

2

2

1

1

Frame 

assembly

Fig.4-4

2. Version I Installation
Mark

 

where the screws will go

 

on

 

the

 

wall,

 

according

 

to

 

the

 

unit mounting

 

holes

 

or

 

dimensions

 

specified

 

in

 

Fig.4-11, Fig.4-12

.

 

The

 

drain

 

pipe

 

for

 

condensate

 

water

 

must

 

be smooth enough to allow unobstructed water 

discharge.
As

 

shown

 

in

 

Fig.4-5

,

 

fasten

 

four

 

screws

 

(

)

 

into

 

a

 

proper 

masonry structure.

   

    

  

 
        

 

      

          

 

      
  

 

  

 

Feet

Fig.4-6b

4. Installation with lifting eye bolts
Use

 

different

 

bolts

 

for

 

the

 

installation,

 

according to

 

the 

installation

 

surroundings.

WOOD STRUCTURE

Put

 

the

 

square

 

timber

 

hori

zontally

 

on

 

the

 

roof

 

beam,

 

and then 

install

 

the

 

hanging

 

bolts.

Timber on beam

Hanging bolts

Embedding

  

bolts.

   (Sliding insert

(Blade shape

 

insert)

Steel bar

  

Embedded bolt 

(Pipe suspension and embedded bolt)

Fig.4-9

CONCRETE BRICKS

  

Fig.4-5

 

Diagram for fixing the unit body

3. Version II Installation
The

 

footings

 

shown

 

in

 

Fig.4-6a,

 

Fig.4-6b

 

are

 

optional.

You

 

can

 

purchase

 

them

 

separately

 

and

 

install

 

them

 

as

 

follows:
1. For

 

the covered equipment,

 

fix

 

the

 

base according

 

to

Fig.4-6a before

hand

.

2. Place the feet alongside the unit to be installed.
3.

 

Place

 

the

 

unit base mounting

 

holes

 

into

 

the 

corresponding

 

feet

 

positioning

 

pin

 

and

 

install the

 

screws 

*2 and

 

*2 to fix the feet, according to

 

Fig.4-6b

.

4.3

 

Indoor Unit Installation

1. Remove the frame (covered equipment)
Remove screws

 

*2 and

 

*2 and then the frame.

Fig.4-6a 

C

overed equipment

Содержание MVD DC2 Series

Страница 1: ...CL23460 CL23476 English Floor Standing MVD DC2 Installation and User Manual www mundoclima com MVD DC2...

Страница 2: ...al shocks and fire Install at a strong and firm location which is able to withstand the equipment s weight If the strength is not enough or installation is not properly done the set will drop and caus...

Страница 3: ...to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indoor unit wires You are not allow to connect the air conditioner with the power sou...

Страница 4: ...ts Mounting Screw 4 All the illustrations of this manual are for explanatory purpose only The appearance functions and physical objects may differ please refer to the actual product Air outlet Air inl...

Страница 5: ...r discharge piping and plastic parts 4 2 Choosing an Installation Site 1 Choose a site that fully complies with the following conditions and user requirements to install the air conditioning unit Well...

Страница 6: ...ion surroundings WOOD STRUCTURE Put the square timber horizontally on the roof beam and then install the hanging bolts Timber on beam Hanging bolts Embedding bolts Sliding insert Blade shape insert St...

Страница 7: ...6 5 Dimensions Liquid side E Gas side F BOLT HOLES A B 200 128 C 47 D Refrigerant pipe connection point Refrigerant pipe connection point Fig 4 11 Covered equipment...

Страница 8: ...12 7 4 5 1240 495 984 375 6 4 12 7 7 1 1360 591 1104 391 9 5 15 9 5 6 1360 591 1104 391 6 4 12 7 G H 915 470 915 470 915 470 1133 470 1253 566 1253 566 200 80 H G C D 8 0 1360 591 1104 391 9 5 15 9 1...

Страница 9: ...ture in during installation 4 5 1 Connecting Pipes Procedure 5 1 1 Measure the necessary length of the connecting pipe and follow the instructions 1 Connect the indoor unit first and then the outdoor...

Страница 10: ...Do not damage the piping 4 6 4 Piping Installation For the installation of the outdoor unit s refrigerant pipe please refer to the installation manual provided with the outdoor unit All gas and liqui...

Страница 11: ...sure all the connections in the piping system are properly sealed to prevent water leaks 5 2 Water Discharge Test Before testing make sure that the water discharge pipe is smooth and check if each con...

Страница 12: ...ng with the power on Do not bind the refrigerant piping power cords and communication wiring together When the power cord and communication wiring are parallel the distance between the two lines must...

Страница 13: ...terial to seal and protect the perforated wires Poor sealing may lead to condensation and entry of small animals and insects that may cause short circuits in parts of the electrical system causing the...

Страница 14: ...Capacity HP number has not been set 8 Test Run 8 1 Precautions Before Test Run Indoor and outdoor units are properly installed Piping and wiring are correct No refrigerant piping system leaks Smooth...

Страница 15: ...ked by dirt or dust water leaks may occur when the unit is Do not allow this unit or its remote control to come into contact Do not touch the unit or its remote control with wet hands as doing so can...

Страница 16: ...o not play with the appliance This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if...

Страница 17: ...l receiver Operation lamp MANUAL OPERATION TIMER DEF FAN ALARM Anti cold air defrosting indicator Check regularly Figure 11 1 Please note how you can best save energy and achieve the best cooling heat...

Страница 18: ...that outlet air is either cooler or hotter than the set room temperature Avoid direct exposure to outlet air as it may be too cool or hot 2 Take out the air filter 3 Clean the air filter During the op...

Страница 19: ...or up to 12 minutes under some operating conditions If the OPERATION LED on the unit s panel is lighting the system is working normally and the unit will start after the intentional delay is complete...

Страница 20: ...e day The outside temperature is unusually high 19 A power cut has occurred the power of the premises has been cut off The remote control batteries are dead Arrange for a professional technician to ch...

Страница 21: ...onditioner operation will stop up to the set time 20 14 3 Remote Control Troubleshooting Warning Certain troubleshooting steps that a professional technician may perform when investigating an error ar...

Страница 22: ...tioned Damaged main PCB E6 E7 Indoor EEV coil error Eb Outdoor unit error Ed MS box PCB malfunction Emergency stop A0 MS self check failure U4 MS failure F8 IDU address repeat Error code display F7 an...

Страница 23: ...SAT 34 93 652 53 57 www mundoclima com C N POLES 249 P1 08013 BARCELONA SPAIN 34 93 446 27 80...

Отзывы: