8
DRY:
This mode is used to decrease the humidity in the room.
COOL:
O
O
The temperature setting are adjustable between 17 C to 30 C. Cooling begins automatically
O
when the room temperature is 1 C above the set point, and stops when the room temperature
O
is 1 C below the set point. The fan will not stop running.
SLEEP:
Press and hold the "SWING" keypad for 2 seconds or use the remote control to activate
the "SLEEP" feature . Press and hold the "SWING" keypad for 2 seconds or use the remote
control again to deactivate the "SLEEP" feature. In the Cooling mode, the cooling
O
temperature set point will increase 1 C per hour after the "SLEEP" mode is selected.
Two hours later, the set point will continue at this temperature and the fan motor will
remain on LOW speed.
This new temperature will be maintained for 7 hours, then the unit exits sleep mode and is off.
Using the "SLEEP" mode will reduce noise creating a comfortable sleeping environment.
Note
:
When activating the SLEEP mode in AUTO mode, the set temperature will not change over time.
The selected time will register in 5 second and the system will automatically revert
back to display the previous temperature setting.
Turning the unit ON or OFF at any time will cancel the Auto Start/Stop function.
AUTO:
The fan motor remains on MED speed in AUTO mode. The unit will select the appropriate
operating mode from FAN, COOL based upon the temperature difference beetwen the actual
and desired room temperature. If the actual room temperature is 2 C above the set point, the
O
unit operates in cooling mode. When the actual room temperatures is not 2 C or higher above
O
set point and not 2 C or lower below the set point, the unit will select the FAN mode.
Note
: 1.If activating the SLEEP mode when the unit is operating on AUTO mode, the fan motor will
changed into LOW speed mode immediately.
OPERATING INSTRUCTIONS (continued)
O