4.    INSPECTING AND HANDLING THE UNIT

At delivery, the package should be checked and any damage should 
be reported immediately to the carrier claims agent.

When handling the unit, take into account the following:

5.    INDOOR UNIT INSTALLATION

5.1   Installation place

          Fragile, handle the unit with care.

Choose on before hand the path along which the unit is to be 
brought in.

Move this unit as originally package as possible.

When lifting the unit , always use protectors to prevent belt 
damage and pay attention to the position of the unit’s centre 
of gravity.

1

2

3

4

Installation Board and Its Direction (unit: mm)

1      Fix the installation board.

Install the installation board horizontally on structural parts in 
the wall with the spaces provided around the plate.

In case of brick, concrete or similar type walls,make 5mmdia, 
holes in the wall. Insert clip anchors for appropriate mounting 
screws.

Fix the installation board on the wall.

5.2   Drilling A Hole and Mounting Installation 
        Board

MUP-09/12-W9

Fig.5-1

Right installation

Avoid installing it in a narrow sapce which has a high 
requirement to noise.

The ceiling is horizontal, and its structure can endure the 
weight of the indoor unit.

The outlet and the inlet are not impeded, and the 
influence of external air is the least.

The air flow can reach throughout the room.

The connecting pipe and drainpipe could be extracted out 
easily.

There is no direct radiation from heaters.

Don't install it in a place whose air contains much salt. If 
this can't be avoided, choose a anticorrosive model.

The indoor unit should be installed in a location that meets 
the following reauirements:

CAUTION

Installing the equipment in any of the following places may lead to 
faults of the equipment (if that is inevitable, consult the supplier):   

A. The site contains mineral oils such as cutting lubricant.
B. Seaside where the air contains much salt.
C. Hotpring area where corrosive gases exist, e.g., sulfide gas.
D. Factories where the supply voltage fluctuates seriously. 
E. Inside a car or cabin.
F.  Place like kitchen where oil permeates.
G. Place where strong electromagnetic waves exist.
H. Place where flammable gases or materials exist.
 I. Place where acid or alkali gases evaporate.
J. Other special environments.

Fig.5-2

ON

S W 2

ON

S W 2

ON

SW6

O

N

ON

ON

462

57

290

915

712

mounting board of indoor unit

the shape of indoor unit

MUP-16/18-W9

315

1070

794

730

65

mounting board of indoor unit

the shape of indoor unit

Fig.5-3

mounting board 
of indoor unit

horizontal line

7

Содержание MUP-W9

Страница 1: ...and owner s manual and information requirements www mundoclima com FR Manual d utilisation et d installation voir www mundoclima com fr DE Benutzer und Installationshandbuch sehen www mundoclima com d...

Страница 2: ...grounded power GND switch Any breach of these specifications involve a breach of the warranty conditions provided by the In line with the company s policy of continual product improvement the aestheti...

Страница 3: ...INSTALLATION MANUAL CONTENTS PRECAUTIONS 4 INSTALLATION INFORMATION 5 ATTACHED FITTINGS 6 INSPECTING AND HANDLING THE UNIT 7 INDOOR UNIT INSTALLATION 7 WIRING CHART 10 WATER PIPE INSTALLATION 9 3...

Страница 4: ...rvision or instruct Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or elect...

Страница 5: ...urce until w including iring and piping the air conditioner is done While following the instructions in this installation manual install drain piping in order to ensure proper drainage and insulate pi...

Страница 6: ...ping tape 5 Wall conduit cover 6 Owner s manual 7 Installation manual 8 seel gasket 8 8 1 1 1 1 1 FUNCTION Secure the installation board This manual 1 Screw ST3 9x25 for installation board 4 For conne...

Страница 7: ...structure can endure the weight of the indoor unit The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room The connecting pi...

Страница 8: ...indoor unit first then the outdoor unit and bend and arrange the pipe carefully Be careful not to let the drain hose slack Insulate both of the auxiliary piping 43 Indoor unit outline Connective pipe...

Страница 9: ...Then move the Indoor Unit from side to side up and down to check if it is hooked securely Because the condensed water from rear of the indoor unit is gathered in Pond Box and is piped out of room Do n...

Страница 10: ...unit wiring diagram for the wiring The air conditioners can connect with Central Control Monitor CCM Before operation please wiring correctly and set system address and network address of indoor units...

Страница 11: ...MPORTANT SAFETY INFORMATION 9 PARTS NAMES OPERATION RANGE HINTS FOR ECONOMICAL OPERATION MAINTENANCE FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES TROUBLESHOOTING 13 14 14 15 15 16 17 ADJ USTING...

Страница 12: ...e air conditioner you purchased depend on model The actual shape shall prevail Air inlet Air outlet Inlet pipe Return pipe Drain pipe 1 2 3 4 Bottom plate Faceplate Display panel Horizontal air deflec...

Страница 13: ...Never let the indoor unit or the remote controller get wet It may cause an electric shock or a fire Never press the button of the remote controller with a hard pointed object The remote controller may...

Страница 14: ...nel Refer to Fig 2 1 This function is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted Two modes including AUTO and FORCED COOL can be sel...

Страница 15: ...or unit and remote controller A wet cloth may be used to clean the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treted duster for wiping or l...

Страница 16: ...just starting if the compressor has not started the indoor unit appears anti cold wind protection because of its overlow outlet temperature In order to prevent the indoor evaporator frosting the syst...

Страница 17: ...and make air smooth Close doors and windows Make curtains in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Symptoms Causes Unit does not start Air flowing normal...

Страница 18: ...ush the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air c...

Страница 19: ...MUP 09 12 W9 MUP 16 18 W9 Model A B C D E 732 915 290 663 233 892 1072 315 813 237 ANNEXED I DIMENSIONS 19...

Страница 20: ...N CL92869 LC04630 or 0 10V output for valve MUP 09 W9 MUP 12 W9 Reserved MUP 16 W9 MUP 18 W9 Optional use MODBUS Voltage V Fan speed shutdown LOW MEDIUM HIGH Table Fan speed control via a 0 10V input...

Страница 21: ...idification modes Query Ts is 0 Fan speed setting 1603 PLC 41604 0x02 Low speed 0x03 Middle speed 0x04 High speed 0x05 Auto speed When setting other parameters returning to abnormal data function code...

Страница 22: ...ept for the 1 bit above other bits in this byte are 0 This byte is read only Baud rate 1640 PLC 41641 The following baud rate support is available 4800 9600 19200 38400 After changing these three para...

Страница 23: ...Z G J U X Z G J U XX Z U J _ U J Z J _ U J U J G j JJ V qV q G J U X Z G J U X Z G J U XX Z U J _ U J Z q q J _ U J U J G j JJ V qV q G J U X Z G J U X Z G J U V XX Z U J _ U J Z J _ U J U J G j JJ V...

Страница 24: ...SAT 34 93 652 53 57 www mundoclima com C N POLES 249 P1 ESPA A SPAIN 34 93 446 27 80 08013 BARCELONA...

Отзывы: