4.    HINTS FOR ECONOMICAL OPERATION 

The following should be noticed to ensure an economical operation. 
(Refer to corresponding chapterfor details) 

Adjust the air flow direction properly to avoid winding toward 
your body. 

Adjust the room temperature properly to get a comfortable 
situation and to avoid supercooling and superheat. 

In cooling, close the curtains to avoid direct sunlight. 

To keep cool or warm air in the room, never open doors or 
windows more often than necessary.

Set the timer for the desired operating time. 

Never put obstructions near the air outlet or the air inlet. Or it 
will cause lower efficiency, even a sudden stop. 

Adjust the air flow direction properly to avoid winding toward 
your body.

Adjust the room temperature properly to get a comfortable 
situation and to avoid supercooling and superheat. 

In cooling, close the curtains to avoid direct sunlight. 

To keep cool or warm air in the room, never open doors or 
windows more often than necessary.

A clogged air filter will reduce cooling or heating efficiency, 
please clean it once two weeks.

5.    AD

J

USTING AIR FLOW DIRECTION 

While the unit is in operation, you can adjust the air flow louver 
to change the flow direction and naturalize the room 
temperature evenly. Thus you can enjoy it more comfortably.

Adjust horizontal air 

Adjust horizontal air deflector by remote controller.

Horizontal air deflector

Fig.5-1

Adjust vertical air 

Open the horizontal air deflector,and then manually adjust 
vertical air deflector.  

Vertical air deflector

Fig.5-2

6.    MAINTENANCE 

CAUTION

Before you clean the air conditioner, be sure the power 
supply is off. 

Check if the wiring is not broken off or disconnected. 

Use a dry cloth to wipe the indoor unit and remote 
controller.

A wet cloth may be used to clean the indoor unit if it is 
very dirty.

Never use a damp cloth on the remote controller.

Do not use a chemically-treted duster for wiping or leave 
such material on the unit for long. 

it may damage or fade the surface of the unit. 

Do not use benzine, thinner, polishing powder, or similar 
solvents for cleaning.

These may cause the plastic surface to crack or deform. 

Cleaning the air filter 

The air filter can prevent the dust or other particulate from 
going inside.

ǂ

In case of blockage of the filter, the working 

efficiency of the air conditioner may greatly decrease . 
Therefore, the filter must be cleaned once two weeks during 
long time usage. 

If the air conditioner is installed in a dust place, clean the air 
filter frequent. 

If the accumulated dust is too heavy to be cleaned, please 
replace the filter with a new one(replaceable air filter is an 
optional fitting). 

Maintenance after a long stop period 

(eg. at the beginning of the season)

Maintenance before a long stop period

(eg. at the end of the season)

          

Check and remove everything that might be blocking inlet
and outlet vents of indoor units and outdoor units. 

Clean air filters and casings of indoor units.
Refer to "Cleaning the air filter" for details on how  to proceed 
and make sure to install cleaned air filters back in the same 
position.

Turn on the power at least 12 hours before operating the unit 
in order to ensure smoother operation. As soon as he power 
is turned on, the remote controller  displays appear. 

Let the indoor units run in fan only operation for about half a 
day in order to dry the interior of the units. 

Clean air filters and casings of indoor units. Refer to " 
Cleaning the air filter" for details on how to proceed and 
make sure to install cleaned air filters back in the same 
position.

 
The filter cleaning should be performed by a suitable 
service provider. 

15

Содержание MUP-W9

Страница 1: ...and owner s manual and information requirements www mundoclima com FR Manual d utilisation et d installation voir www mundoclima com fr DE Benutzer und Installationshandbuch sehen www mundoclima com d...

Страница 2: ...grounded power GND switch Any breach of these specifications involve a breach of the warranty conditions provided by the In line with the company s policy of continual product improvement the aestheti...

Страница 3: ...INSTALLATION MANUAL CONTENTS PRECAUTIONS 4 INSTALLATION INFORMATION 5 ATTACHED FITTINGS 6 INSPECTING AND HANDLING THE UNIT 7 INDOOR UNIT INSTALLATION 7 WIRING CHART 10 WATER PIPE INSTALLATION 9 3...

Страница 4: ...rvision or instruct Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or elect...

Страница 5: ...urce until w including iring and piping the air conditioner is done While following the instructions in this installation manual install drain piping in order to ensure proper drainage and insulate pi...

Страница 6: ...ping tape 5 Wall conduit cover 6 Owner s manual 7 Installation manual 8 seel gasket 8 8 1 1 1 1 1 FUNCTION Secure the installation board This manual 1 Screw ST3 9x25 for installation board 4 For conne...

Страница 7: ...structure can endure the weight of the indoor unit The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room The connecting pi...

Страница 8: ...indoor unit first then the outdoor unit and bend and arrange the pipe carefully Be careful not to let the drain hose slack Insulate both of the auxiliary piping 43 Indoor unit outline Connective pipe...

Страница 9: ...Then move the Indoor Unit from side to side up and down to check if it is hooked securely Because the condensed water from rear of the indoor unit is gathered in Pond Box and is piped out of room Do n...

Страница 10: ...unit wiring diagram for the wiring The air conditioners can connect with Central Control Monitor CCM Before operation please wiring correctly and set system address and network address of indoor units...

Страница 11: ...MPORTANT SAFETY INFORMATION 9 PARTS NAMES OPERATION RANGE HINTS FOR ECONOMICAL OPERATION MAINTENANCE FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES TROUBLESHOOTING 13 14 14 15 15 16 17 ADJ USTING...

Страница 12: ...e air conditioner you purchased depend on model The actual shape shall prevail Air inlet Air outlet Inlet pipe Return pipe Drain pipe 1 2 3 4 Bottom plate Faceplate Display panel Horizontal air deflec...

Страница 13: ...Never let the indoor unit or the remote controller get wet It may cause an electric shock or a fire Never press the button of the remote controller with a hard pointed object The remote controller may...

Страница 14: ...nel Refer to Fig 2 1 This function is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted Two modes including AUTO and FORCED COOL can be sel...

Страница 15: ...or unit and remote controller A wet cloth may be used to clean the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treted duster for wiping or l...

Страница 16: ...just starting if the compressor has not started the indoor unit appears anti cold wind protection because of its overlow outlet temperature In order to prevent the indoor evaporator frosting the syst...

Страница 17: ...and make air smooth Close doors and windows Make curtains in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Symptoms Causes Unit does not start Air flowing normal...

Страница 18: ...ush the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air c...

Страница 19: ...MUP 09 12 W9 MUP 16 18 W9 Model A B C D E 732 915 290 663 233 892 1072 315 813 237 ANNEXED I DIMENSIONS 19...

Страница 20: ...N CL92869 LC04630 or 0 10V output for valve MUP 09 W9 MUP 12 W9 Reserved MUP 16 W9 MUP 18 W9 Optional use MODBUS Voltage V Fan speed shutdown LOW MEDIUM HIGH Table Fan speed control via a 0 10V input...

Страница 21: ...idification modes Query Ts is 0 Fan speed setting 1603 PLC 41604 0x02 Low speed 0x03 Middle speed 0x04 High speed 0x05 Auto speed When setting other parameters returning to abnormal data function code...

Страница 22: ...ept for the 1 bit above other bits in this byte are 0 This byte is read only Baud rate 1640 PLC 41641 The following baud rate support is available 4800 9600 19200 38400 After changing these three para...

Страница 23: ...Z G J U X Z G J U XX Z U J _ U J Z J _ U J U J G j JJ V qV q G J U X Z G J U X Z G J U XX Z U J _ U J Z q q J _ U J U J G j JJ V qV q G J U X Z G J U X Z G J U V XX Z U J _ U J Z J _ U J U J G j JJ V...

Страница 24: ...SAT 34 93 652 53 57 www mundoclima com C N POLES 249 P1 ESPA A SPAIN 34 93 446 27 80 08013 BARCELONA...

Отзывы: