air filter 

net of clear air 

mesh enclosure of clear air 

1. Dismantle the air filter.   
 
2. Clean the air filter  

The air filter can prevent the dust or other particulate from 
going inside. In case of blockage of the filter, the working 
efficiency of the air conditioner may greatly decrease . 
 
Therefore, the filter must be cleaned once two weeks during 
long time usage. 
 
Clean the air filter with vacuum cleaner or water. 
 
a.The air-in side should face up when using vacuum  
    cleaner. (Refer to 

Fig.6-2

b.The air-in side should face down when using clean water.  
    (Refer to 

Fig.6-3

 
If the dust accumulation is too heavy, please use soft bursh and 
natural detergent to clean it and dry in the cool place. 

Fig.6-1

Fig.6-3

Do not dry out the air filter under direct sunshine or with fire. 
 

 

CAUTION 

3. Re-install the air filter. 
 
4. Install and close the air-in grill in the reverse orders of step  
   1 and 2 and connect the control box cables to the  corre 
   sponding terminators of the main body.   

7.    FOLLOWING SYMPTOMS ARE NOT AIR 

       CONDITIONER TROUBLES 

Symptom 1: The system does not operate 

Symptom 2: Change into the fan mode during cooling
                      mode 

The air conditioner does not start immediately after the ON/OFF 
button on the romote controller is pressed.
If the operation lamp lights, the system is in normal condition.To 
prevent overloading of the compressor motor, the air 
conditioner starts 3 minutes  after  it  is turned ON. 

If the operation lamp and the "PRE-DEF indicator(cooling and 
heating type) or fan only indicator(cooling only type)" light, it 
means you choose the heating model, When just starting, if the 
compressor has not started, the indoor unit  appears "anti cold 
wind" protection because of its overlow outlet temperature. 

In order to prevent the indoor evaporator frosting, the system 
will change into fan mode automatically, restore to the cooling 
mode after soon. 

When the room temperature drops to the set temperature, the 
compressor goes off and the indoor unit changes to fan mode; 
when the temperature rises up, the compressor starts again. It 
is same in the heating mode. 

Symptom 3: White mist comes out of a unit 

Symptom 4: Noise of air conditioners cooling

When humidity is high during cooling operation If the interior of 
an indoor unit is extremely contaminated,the temperature 
distribution inside a room becomes uneven. It is necessary to 
clean the interior of the indoor unit.Ask your dealer for details on 
cleaning the unit.This operation requires a qualified service 
person.

When the system is changed over to heating operation after 
defrost operation Moisture generated by defrost becomes 
steam and is exhausted.

A continuous low "shah" sound is heard when the system is in 
cooling operation or at a stop.
When the drain pump (optional accessories) is in operation,this 
noise is heard. 

A "pishi-pishi" squeaking sound is heard when the system stops 
after heating operation.
Expansion and contraction of plastic parts caused by 
temperature change make this noise.

Symptom 5: Dust comes out of the unit

Symptom 6: The units can give off odours 

When the unit is used for the first time in a long time.
This is because dust has gotten into the unit. 

When the tone of operating noise changes.
This noise is caused by the change of frequency. 

The unit can absorb the smell of rooms, furniture, cigarettes, 
etc., and then emit it again.

Fig.6-2

16

Содержание MUP-W9

Страница 1: ...and owner s manual and information requirements www mundoclima com FR Manual d utilisation et d installation voir www mundoclima com fr DE Benutzer und Installationshandbuch sehen www mundoclima com d...

Страница 2: ...grounded power GND switch Any breach of these specifications involve a breach of the warranty conditions provided by the In line with the company s policy of continual product improvement the aestheti...

Страница 3: ...INSTALLATION MANUAL CONTENTS PRECAUTIONS 4 INSTALLATION INFORMATION 5 ATTACHED FITTINGS 6 INSPECTING AND HANDLING THE UNIT 7 INDOOR UNIT INSTALLATION 7 WIRING CHART 10 WATER PIPE INSTALLATION 9 3...

Страница 4: ...rvision or instruct Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or elect...

Страница 5: ...urce until w including iring and piping the air conditioner is done While following the instructions in this installation manual install drain piping in order to ensure proper drainage and insulate pi...

Страница 6: ...ping tape 5 Wall conduit cover 6 Owner s manual 7 Installation manual 8 seel gasket 8 8 1 1 1 1 1 FUNCTION Secure the installation board This manual 1 Screw ST3 9x25 for installation board 4 For conne...

Страница 7: ...structure can endure the weight of the indoor unit The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room The connecting pi...

Страница 8: ...indoor unit first then the outdoor unit and bend and arrange the pipe carefully Be careful not to let the drain hose slack Insulate both of the auxiliary piping 43 Indoor unit outline Connective pipe...

Страница 9: ...Then move the Indoor Unit from side to side up and down to check if it is hooked securely Because the condensed water from rear of the indoor unit is gathered in Pond Box and is piped out of room Do n...

Страница 10: ...unit wiring diagram for the wiring The air conditioners can connect with Central Control Monitor CCM Before operation please wiring correctly and set system address and network address of indoor units...

Страница 11: ...MPORTANT SAFETY INFORMATION 9 PARTS NAMES OPERATION RANGE HINTS FOR ECONOMICAL OPERATION MAINTENANCE FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES TROUBLESHOOTING 13 14 14 15 15 16 17 ADJ USTING...

Страница 12: ...e air conditioner you purchased depend on model The actual shape shall prevail Air inlet Air outlet Inlet pipe Return pipe Drain pipe 1 2 3 4 Bottom plate Faceplate Display panel Horizontal air deflec...

Страница 13: ...Never let the indoor unit or the remote controller get wet It may cause an electric shock or a fire Never press the button of the remote controller with a hard pointed object The remote controller may...

Страница 14: ...nel Refer to Fig 2 1 This function is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted Two modes including AUTO and FORCED COOL can be sel...

Страница 15: ...or unit and remote controller A wet cloth may be used to clean the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treted duster for wiping or l...

Страница 16: ...just starting if the compressor has not started the indoor unit appears anti cold wind protection because of its overlow outlet temperature In order to prevent the indoor evaporator frosting the syst...

Страница 17: ...and make air smooth Close doors and windows Make curtains in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Symptoms Causes Unit does not start Air flowing normal...

Страница 18: ...ush the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air c...

Страница 19: ...MUP 09 12 W9 MUP 16 18 W9 Model A B C D E 732 915 290 663 233 892 1072 315 813 237 ANNEXED I DIMENSIONS 19...

Страница 20: ...N CL92869 LC04630 or 0 10V output for valve MUP 09 W9 MUP 12 W9 Reserved MUP 16 W9 MUP 18 W9 Optional use MODBUS Voltage V Fan speed shutdown LOW MEDIUM HIGH Table Fan speed control via a 0 10V input...

Страница 21: ...idification modes Query Ts is 0 Fan speed setting 1603 PLC 41604 0x02 Low speed 0x03 Middle speed 0x04 High speed 0x05 Auto speed When setting other parameters returning to abnormal data function code...

Страница 22: ...ept for the 1 bit above other bits in this byte are 0 This byte is read only Baud rate 1640 PLC 41641 The following baud rate support is available 4800 9600 19200 38400 After changing these three para...

Страница 23: ...Z G J U X Z G J U XX Z U J _ U J Z J _ U J U J G j JJ V qV q G J U X Z G J U X Z G J U XX Z U J _ U J Z q q J _ U J U J G j JJ V qV q G J U X Z G J U X Z G J U V XX Z U J _ U J Z J _ U J U J G j JJ V...

Страница 24: ...SAT 34 93 652 53 57 www mundoclima com C N POLES 249 P1 ESPA A SPAIN 34 93 446 27 80 08013 BARCELONA...

Отзывы: