12. Installation

12.1 Before Installation 

Please check whether the accessories are of full scope. If there are some fittings free from use, please restore 

them carefully. 

12.2 Installation space 

(Refer to fig.12.1, fig.12.2, fig.12.3 and table 12.1 for specification.) 

The indoor unit should be installed in a location that meets the following requirements: 

 

There is enough room for installation and maintenance. 

 

The ceiling is horizontal, and its structure can bear the weight of the indoor unit. 

 

The outlet and the inlet are not impeded, and the influence of external air is the least. 

 

The air flow can reach throughout the room. 

 

The connecting water pipe and drainpipe could be extracted out easily. 

 

There is no direct radiation from heaters. 

Caution:

 Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least 1 meter away from 

televisions and radios. This is to prevent image interference and noise in those electrical appliances. (Noise may 
be generated depending on the conditions under which the electric wave is generated, even if 1 meter is kept.) 

12.3 Installation procedures for fresh air intake duct connection 

Preparing the connection hole 

 

Cut off the knockout hole on the side plate with a nipper. 

 

Cut the inner insulation of the hole portion with a cutter. 

Placing the insulation 

 

Put the insulation tightly around the hole of the unit as shown. 

 

The  ends  of  the  side  plate  and  the  inner  insulation  must  be  completely  adhered  without  leaving  any 

clearance along the circumference of the hole. Make sure the inner surface of insulation tightly contacts 

the inner insulation edge and the side plate. (refer to fig.12.5) 

12.4 Install the Main Body 

A. The existing ceiling (to be horizontal) 

a.  Cut a quadrangular hole of 880×880mm in the ceiling according to the shape of the installation paper board. 

 

The center of the hole should be at the same position of that of the air conditioner body. 

 

Determine the lengths and outlets of the connecting pipe, drain pipe and cables. 

 

To balance the ceiling and to avoid vibration, please enforce the ceiling when necessary. 

b.  Select the position of installation hooks according to the hook holes on the installation board. 

 

Drill  four  holes  of  Ø12mm,  50~55mm  deep  at  the  selected  positions  on  the  ceiling.  Then  embed  the 

expansible hooks (fittings). 

 

Face the concave side of the installation hooks toward the expansible hooks. Determine the length of the 

installation hooks from the height of ceiling, and then cut off the unnecessary part. 

 

If the ceiling is extremely high, please determine the length of the installation hook according to facts. 

c. 

Adjust the hexangular nuts on the four installation hooks evenly, to ensure the balance of the body. 

 

If the drainpipe is awry, leakage will be caused by the malfunction of the water-level switch. 

 

 

28

 

 

 

  Four-way Cassette DC Fan Coil Unit  

 

Содержание MUCS-20-W9

Страница 1: ...www mundoclima com Cassette 4 Ways FCU DC Service manual English CL04433 to CL04435 MUCS W9...

Страница 2: ...nal Appearance 3 2 Features 3 3 Product lineup 4 4 Accessories 5 5 Specifications 6 6 Capacity Table 7 7 Sound Levels 26 8 Dimension 26 9 Service Spaces 30 10 Wiring Diagrams 31 11 Troubleshooting 32...

Страница 3: ...high efficiency Wireless remote control with LED display wired control is optional Safety grill for safety maintenance Built in drain water pump with 750mm pumping head Optional extended drainage pan...

Страница 4: ...durable motor The motor bearing can operate 80 000 hours continuously and easy for maintenance Low noise Advanced 3 D spiral fan design reduces air resistance and operating sound The motor bearing wi...

Страница 5: ...t M6 4 Tubing Fittings 2 Soundproof insulation sheath Drainpipe Fittings 1 Out let pipe 1 Out let pipe sheath 1 Out let pipe clasp 5 Tightening band Remote controller Its Frame 1 Remote controller R05...

Страница 6: ...7 Panel Net dimensions W H D mm 950 45 950 950 45 950 Packing size W H D mm 1035 90 1035 1035 90 1035 Net weight kg 6 6 Gross weight kg 9 9 Body Net dimensions W H D mm 840 300 840 840 300 840 Packin...

Страница 7: ...1 21 27 27 19 6 93 3 06 1 49 38 84 6 89 3 61 1 48 38 51 6 86 4 15 1 47 38 18 6 82 4 69 1 47 37 86 6 79 5 22 1 46 37 54 20 7 89 3 65 1 7 48 61 7 86 4 19 1 69 48 21 7 82 4 73 1 68 47 82 7 78 5 27 1 67...

Страница 8: ...27 3 24 3 24 0 7 10 18 3 85 3 85 0 83 13 63 20 3 38 2 15 1 1 10 64 3 34 2 69 0 72 10 71 3 4 3 09 1 1 10 98 3 88 3 79 0 83 13 77 5 15 0 92 0 92 0 16 0 86 1 38 1 38 0 24 1 29 2 27 2 27 0 39 2 65 2 94 2...

Страница 9: ...22 85 6 7 6 31 1 44 24 82 7 35 7 35 1 58 29 07 19 8 98 3 97 1 93 40 84 8 93 4 69 1 92 40 48 8 89 5 4 1 91 40 12 8 84 6 11 1 9 39 77 8 8 6 8 1 89 39 42 20 10 25 4 74 2 2 51 23 10 2 5 46 2 19 50 8 10 1...

Страница 10: ...3 3 0 73 7 21 4 21 4 21 0 91 10 77 5 02 5 02 1 08 14 49 20 4 17 2 72 1 44 10 2 4 21 3 44 0 91 10 74 4 38 4 03 0 94 11 51 5 03 4 95 1 08 14 57 5 15 1 22 1 22 0 21 1 03 1 82 1 82 0 31 1 54 2 63 2 63 0 4...

Страница 11: ...1 95 37 53 9 43 8 74 2 02 40 15 10 27 10 18 2 21 46 48 19 12 67 5 59 2 72 66 32 12 58 6 57 2 7 65 58 12 5 7 53 2 68 64 84 12 42 8 48 2 67 64 12 12 34 9 42 2 65 63 4 20 14 39 6 63 3 09 82 52 14 3 7 6 3...

Страница 12: ...5 6 4 9 4 66 1 05 11 67 5 96 5 96 1 28 17 61 7 06 7 06 1 52 23 45 20 5 98 3 58 1 96 17 57 5 72 4 39 1 23 16 33 6 25 5 63 1 35 19 09 7 1 6 91 1 53 23 68 5 15 1 9 1 9 0 33 1 92 2 8 2 8 0 48 2 84 3 96 3...

Страница 13: ...62 0 38 5 04 5 98 0 35 4 24 5 33 0 31 3 46 4 66 0 27 2 59 55 5 10 5 1 83 70 77 9 88 1 72 63 65 9 27 1 62 56 89 8 66 1 51 50 5 8 9 85 1 07 28 02 9 23 1 25 05 8 62 0 94 22 24 8 01 0 87 19 59 10 9 4 0 8...

Страница 14: ...0 59 5 26 15 9 81 0 57 4 97 8 88 0 51 4 2 7 94 0 46 3 44 6 98 0 4 2 6 55 5 15 23 2 65 67 13 14 33 2 5 60 33 13 43 2 34 53 89 12 54 2 19 47 82 8 14 33 1 56 26 76 13 44 1 46 23 92 12 54 1 36 21 23 11 65...

Страница 15: ...10 15 0 59 7 9 01 0 52 4 86 7 62 0 44 3 07 5 7 0 33 2 17 55 5 16 94 2 95 115 9 15 93 2 78 104 13 14 93 2 6 92 99 13 93 2 43 82 46 8 15 82 1 72 45 82 14 81 1 61 40 9 13 81 1 5 36 26 12 81 1 39 31 88 10...

Страница 16: ...7 Sound Levels H M L dB A 44 40 34 MUCS 24 W9 MUCS 36 W9 48 44 41 49 43 39 MUCS 20 W9 19 Four way Cassette DC Fan Coil Unit...

Страница 17: ...MUCS 20 W9 20 Four way Cassette DC Fan Coil Unit MUCS 24 W9...

Страница 18: ...MUCS 36 W9 21 Four way Cassette DC Fan Coil Unit...

Страница 19: ...8 Dimension Model A B C D E F MUCS 20 W9 180 140 85 350 145 195 MUCS 24 W9 MUCS 36 W9 180 140 155 350 155 205 22 Four way Cassette DC Fan Coil Unit...

Страница 20: ...9 Service Spaces Model A B C 230 170 260 300 190 330 MUCS 20 W9 MUCS 24 W9 MUCS 36 W9 23 Four way Cassette DC Fan Coil Unit...

Страница 21: ...CN13 CN19 CN18 POWER IN 3 2 V1 1 N L V2 XT1 4 RED RED BLUE BLUE RED BLUE BLACK BLUE ONLY 4 PIPE ONLY 4 PIPE G Y ALARM CN3 L N POWER S4 1 2 ON ENC1 S2 1 2 3 4 ON S1 1 2 3 4 ON S3 1 2 3 4 ON ON OFF CN1...

Страница 22: ...ECTOR SWITCH OVER HEAT H AUXILIARY HEATER CS WATER LEVEL SWITCH PUMP PUMP MOTOR Notes 1 SW1 must be set as the Table B 2 Two control mode is only connected with a valve valve 1 Four control models are...

Страница 23: ...oller Wait for the comeback of power Switch on the power Replace the fuse Replace the batteries or check the controller Air flowing normally but completely can t cooling Temperature is not set correct...

Страница 24: ...top up to the set time The TIMER on indicator goes off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the a...

Страница 25: ...insulation tightly around the hole of the unit as shown The ends of the side plate and the inner insulation must be completely adhered without leaving any clearance along the circumference of the hol...

Страница 26: ...become loose because of concrete shrinking b After installing the body please fasten the installation paper board onto the air conditioner with bolts M6 12 to determine in advance the sizes and posit...

Страница 27: ...n floor or against the wall or on bulgy objects Never crash or strike it 1 Remove the air inlet grill a Slide two grid switches toward the middle at the same time and then pull them up Refer to fig 12...

Страница 28: ...ir in grid in the procedure of reversed order 6 Relocate the installation cover a Fasten the rope of installation cover on the bolt of the installation cover b Press the installation cover into the pa...

Страница 29: ...water receiver through the stow tube 2 Turn on the power and operate the air conditioner under the COOLING mode Listen to the sound of the drain pump Check whether the water is discharged well a lag...

Страница 30: ...in power distribution The distribution has to be of low impedance normally the required impedance reaches at a 32A fusing point 2 No other equipment has to be connected with this power line 3 For deta...

Страница 31: ...12 7 2 Wiring figure 34 Four way Cassette DC Fan Coil Unit...

Страница 32: ...e user s requirement install the remote controller frame where the remote controller s signal can reach the indoor unit smoothly Test operation Set the air conditioner under the mode of COOLING with t...

Страница 33: ...SAT 34 93 652 53 57 www mundoclima com C N POLES 249 P1 ESPA A SPAIN 34 93 446 27 80 08013 BARCELONA...

Отзывы: