Wiring Diagrams
Indoor Units
11
MUCSR-60-H6T
SWITCH
ENC1
(FOR POWER)
SWITCH
FOR TEMP.COMPENSATION
SW6
E function
SWITCH
FOR MAIN-SLAVE SETTING
SW5
SWITCH
FOR AUTO-RESTART SETTING
SW3
SWITCH
FOR FAN MOTER CONTROL
THEN NO POWER REQUEST.
SW2
A
Reactor
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0~15
32~47
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
16~31
48~63
According
to the
EEPROM
setting
CN13
DISPLAY
BOARD
TO WIRE
CONTROLLER
10
T2
T1
CN6
4
MIDDLE PIPE TEMP.
ROOM TEMP.
BLACK
WHITE
CN10(CN10A)
M
PUMP
2
INDOOR UNIT
MAINBOARD
CN40
TO WIRE
CONTROLLER
4
C
N
23
O
N
-
O
F
F
Remote
Control
C
N
3
3
A
L
A
R
M
Alarm
Output
Outer Driver DC Motor
Y/G
DC MOTOR
DRIVER MODLE
C
N
1
3
C
N
3
3
CN15
5
M
R
ED
(B
R
O
W
N
)
CN1
BL
UE
(B
LA
CK
)
L
N
Y/G
CN5
WATER LEVEL SWITCH
CN2
Q E P
To CCM
Comm.Bus
CN7
T2B
OUTER PIPE TEMP.
P1
Y/G
CN3
JR6
JR6
To OUTDOOR
Comm.Bus
S2
S1
P4
E Y X
Fe
rri
te
b
ea
d
Fe
rri
te
b
ea
d
5
L
N
L
N
C
N
1
MUCSR-24-H6, MUCSR-30-H6, MUCSR-36-H6, MUCSR-42-H6, MUCSR-48-H6
CN16
CN14
SWING
MOTOR
XS9
XP9
XS10
XP10
FUNCTION OF SWITCH
12000W-14000W(5.0HP)
6
9
8
7
4
5
/
9100W-10500W(4.0HP)
7500W-9000W (3.2HP)
5400W-7100W(2.5HP)
4000W-5300W(2.0HP)
NUMBER
SWITCH
ENC1
(FOR POWER)
POWER
CN55
CN66
TO SWING
BOARD
XS2
XP2
TO GO-UP-AND
-DOWN BOARD
XS2
XP2
SWITCH
FOR TEMP.COMPENSATION
SW6
ON
6
S T A T E
V A L U E
4
2
E function
SWITCH
FOR MAIN-SLAVE SETTING
SW5
ON
S T A T E
M O D E
M A I N
N O S L A V E
M A I N
M A I N
S L A V E
SWITCH
FOR AUTO-RESTART SETTING
SW3
ON
S T A T E
M O D E
R E M E M B E R
N O _ R E M E M B E R
SWITCH
FOR FAN MOTER CONTROL
THEN NO POWER REQUEST.
SW2
ON
S T A T E
M O D E
F A N O N
F A N O F F
8
A
SWITCH FOR CCM UNIT ADDRESS
RED
Reactor
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0~15
S2
+
S1
ADDRESS
ON
1 2
ON
1 2
ON
1 2
ON
1 2
F a c t o r y
S e t t i n g
F a c t o r y
S e t t i n g
F a c t o r y
S e t t i n g
32~47
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
16~31
48~63
S2
+
S1
ADDRESS
Factory
Setting
Factory
Setting
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
ON
ON
ON
RED
F a c t o r y
S e t t i n g
24
15
FAN MOTOR STOP-TEM
SW1
ON
1 2
ON
1 2
ON
1 2
ON
1 2
Anti-cold air
According
to the
EEPROM
setting
Factory setting
14500W-16000W(6.0HP)
CN13
DISPLAY
BOARD
TO WIRE
CONTROLLER
10
T2
T1
CN6
4
MIDDLE PIPE TEMP.
ROOM TEMP.
BLACK
WHITE
CN10(CN10A)
M
PUMP
2
INDOOR UNIT
MAINBOARD
TO WIRE
CONTROLLER
C
N
23
O
N - O
F
F
Remote
Control
C
N
3
3
A
L
A
R
M
Alarm
Output
Outer Driver DC Motor
Y/G
DC MOTOR
DRIVER MODLE
C
N
1
3
C
N
3
3
CN15
M
Inner Driver
DC Motor
5
5
M
R
ED
(B
R
O
W
N
)
CN1
BL
UE
(B
LA
CK
)
L
N
Y/G
CN5
WATER LEVEL SWITCH
CN2
Q E P
To CCM
Comm.Bus
CN7
T2B
OUTER PIPE TEMP.
P1
Y/G
CN3
JR6
JR6
To OUTDOOR
Comm.Bus
S2
S1
P4
E Y X
5
L
N
TO OUTDOOR UNIT
L
N
FOR OUTDOOR POWER SUPPLY
POWER
C
N
1
SWING
MOTOR
MAGNETIC RING
MAGNETIC RING
MAGNETIC RING
HA/HB
ADSS
0~F
NETADDRESS
CODE
0~15
FACTORY SETTING
FOR SETTING WIRECONTROL ADDRESS
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
CL94907
CL94848
Models 18 to 48k
Model 60k
MUCSR-48-H6, MUCSR-48-H6T, MUCSR-60-H6T
Содержание MUCR-H6 Series
Страница 15: ...Air Velocity Distributions Reference Data Indoor Units 13 30 42K Cooling Heating ...
Страница 16: ...Air Velocity Distributions Reference Data 14 Indoor Units 48 60K Cooling Heating ...
Страница 21: ...Field Wiring Indoor Units 19 10 Field Wiring ...
Страница 30: ...Static Pressure 28 Indoor Units 5 Static Pressure MUCR 12 H6 MUCR 18 H6 ...
Страница 31: ...Static Pressure Indoor Units 29 MUCR 24 H6 MUCR 30 H6 ...
Страница 32: ...Static Pressure 30 Indoor Units MUCR 36 H6 MUCR 42 H6 MUCR 48 H6 MUCR 48 H6T MUCR 60 H6T ...
Страница 41: ...Service Space Indoor Units 39 3 Service Space ...
Страница 52: ...50 Indoor Units 10 Field Wiring ...
Страница 61: ...Field Wiring Indoor Units 59 10 Field Wiring MUCSR 12 H6 MUCSR 18 H6 ...
Страница 64: ...Dimensions 62 Outdoor Units Model Unit mm W D H W1 A B 48 60 952 415 1333 1045 634 404 ...
Страница 95: ...Refrigerant pipe installation Installation 93 ...