When the protection equipment starts, please shut down the 

manual power switch, and restart operation after problem is

solved.

NOTE

3.2 About power cut

If power is cut during operation, stop all the operation immediately.

Power comes again. The lamp on the display panel of indoor unit 
flashes. And then unit will auto-restart.

Mishandling in operation:
If mishandling happens because of lighting or mobile wireless, 
please shut off the manual power switch, and turn on again, then
push the ON/OFF button.

3.3 Heating capacity

The heating operation is a heat-pump process that heat will be 
absorbed from outdoor air and released in doors. Once the 
outdoor temperature is decreased, heating capacity decreased 
corredpindingly.

Other heating equipment is suggested to be used together when 
outdoor temperature is too low.

In some extreme cold upland that buy another inddoor unit 
equipped electrical heater will obtain better performance.(Refer 
to indoor unit owner’s manual for details)

NOTE

The motor in Indoor Unit will continue running for 20~30 seconds 
for to remove residual heat when the Indoor Unit recoeiving OFF
command during heating operation.

If the air conditioner malfunction occurs because of disturb, 
pleasereconnect the air conditioner to power, then turn on it 
again.

1.

2.

A protection feature prevents the air conditioner from being 
activated for approximately 5 minuites when it restarts 
immediately after operation.

The indoor unit of the intelligent inverter centralized air 
conditioner can be controlled solely, but the indoor unit in the 
same system can not run cooling and heating at the same time.

3.6 Features of heating operation

Warm air will not be blown out immediately at the beginning of 
the heating operation, 3~5 minutes ago (depends on the indoor 
and outdoor temperature), until the indoor heat exchanger 
become hot, then blows out warm air.

During operation, the fan motor in the outdoor unit may stop 
running under high temperature.

During Fan Operation, if other Indoor Units are running on 
Heating Mode, the fan may stop in order to prevent sending 
heat  wind.

3.7 Defrost in the heating operation

During heating operation, outdoor unit sometimes will frost. To 
increase efficiency, the unit will start defrosting automatically 
(about 2~10 minutes), and then water will be drained out from
outdoor unit.

During defrosting, both the fan motors in the outdoor unit and
indoor unit will stop running.

When the Cooling and Heating operation confront with each 
other, the Indoor Unit which are running on Cooling Mode would
stop and there will be Standby or No Priority displayed in the 
Control Panel. Those Indoor Units which are running on Heating
Mode will run continuously. 

If  the Air Conditioner Administrator has set running mode, 
then the air conditioner  can not run on modes other than the 
presetted.Standby or No Priority will be displayed in the 
Control Panel.

3.4 Five-minute protection feature

3.5 Cooling and heating operation

Owner's manual

18

Mini MVD V6M

Содержание MINI MVD V6M

Страница 1: ...English MVD www mundoclima com Installation and owner s manual MINI MVD V6M OUTDOOR UNIT and information requirements CL23274 to CL23275 MVD V280W DGN1 MVD V335W DGN1...

Страница 2: ...d use This unit must be installed by a professional according RD 795 2010 RD 1027 2007 and RD 238 2013 The power supply must be SINGLE PHASE one phase L and one neutral N with his grounded power GND s...

Страница 3: ...ly if there are possible damage Do not install in a place that might increase the vibration of the unit To avoid personal injury with sharp edges be careful when handling parts Perform installation wo...

Страница 4: ...of the conventional refrigerant take out the flare nut attached to the main unit of the air conditioner and use it Before installation Be careful to the following items before installation Air purge...

Страница 5: ...or unit power cord and connecting wire at least 1m away from TV set or radio to prevent noise or picture interference Strong wind Strong wind 3 2 Installation space Unit mm 300 600 300 0 0 0 3 Wall or...

Страница 6: ...the frozen condensed water will block up the water outlet please pull out the rubber stopper of the reserve water outlet If that still fails to satisfy for the water draining please knock open the ot...

Страница 7: ...connected to the indoor unit is at least 0 5m 4 4 Connecting method main pipe The branch pipes of indoor unit The pipe after the first branch do not drect connect with the indoor unit The pipe after...

Страница 8: ...g nut 15 9 Flaring nut 6 4 Flaring nut Wall mounted 56 15 9 Flaring nut 9 5 Flaring nut 6 4 Flaring nut 9 5 Flaring nut 9 5 Flaring nut One sided air outlet 18 45 12 7 Flaring nut 6 4 Flaring nut One...

Страница 9: ...e gas side main pipe size Inner branch pipes are a f the size selection please refers to Table4 6 Note The max length of the branch pipe should not longer than 15m Indoor unit branch pipe The main pip...

Страница 10: ...t to be Added Using vacuum pump to do the vacuum never using refrigerant to expel the air Vacuuming should be done from both liquid side and gas side simultaneously Calculate the added refrigerant acc...

Страница 11: ...rol system connection of the outdoor unit P Q E L N P Q E L N P Q E L N P Q E L N L2 L3 N L1 K2 E O K1 A E Y E P X Q E Power supply for the outdoor unit monitor Outdoor unit Reserved Optional L N K1 K...

Страница 12: ...he signal cable insert electric wires in their respective electric wire pipes and reserve a proper inter wire distance distance between power cables lower than 10 A 300 mm lower than 50 A 500 mm Use a...

Страница 13: ...NOTE Single phase indoor unit Wire controller The reserved wire control function is indicated in broken line table users can purchase the wire controller when necessary in broken line table users can...

Страница 14: ...tilator A Ventilation peristome Leak hunting siren should be installed in places easily keep refrigerant Indoor unit Outdoor unit Indoor unit Room full of leak refrigerant All refrigerant has run up F...

Страница 15: ...ween main board and compressor drive board Inverter module protection Qty of indoor units mismatching High pressure sensor error M HOME for the indoor and outdoor units does not match Phase sequence e...

Страница 16: ...equipment Failure to observe a warning may result in death The appliance shall be installed in accordance with national wiring regulations Do not use the air conditioner for other purposes In order to...

Страница 17: ...t supervision When capacity of indoor unit greater than the sum of 100 capacity of indoor unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in order to ensur...

Страница 18: ...starts immediately after operation The indoor unit of the intelligent inverter centralized air conditioner can be controlled solely but the indoor unit in the same system can not run cooling and heati...

Страница 19: ...ble Irrecoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable P8 F1 E1 High pressure protection M HOME for the indoor and outdoor units does not match Display F...

Страница 20: ...d when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after h...

Страница 21: ...indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is to...

Страница 22: ...r goes off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatically start and...

Страница 23: ...3 6 4 2 6 732C 3 2C 87 5 3 6 37 3 37 62 and hydrogen sulphide G F7 2 88 8 7 62 26 5 26 63 2 5 E6 3 where the air conditioning is on for 24 hours a day As the use of the unit for many years will eventu...

Страница 24: ...oad at given outdoor temperatures Tj Prated c Pdc Pdc Pdc Pdc Cdc 0 25 33 5 kW Seasonal space cooling energy efficiency s c 199 8 Symbol Value Unit Off mode Thermosat off mode Crankcase heater mode St...

Страница 25: ...d heating capacity Degradation co efficient for heat pumps Declared heating capacity for part load at indoor teperature 20 and outdoor temperatures Tj Declared coefficient of performance or gas utilis...

Страница 26: ...y factor for part load at given outdoor temperatures Tj Prated c Pdc Pdc Pdc Pdc Cdc 0 25 28 0 kW Seasonal space cooling energy efficiency s c 201 0 Symbol Value Unit Off mode Thermosat off mode Crank...

Страница 27: ...ed heating capacity Degradation co efficient for heat pumps Declared heating capacity for part load at indoor teperature 20 and outdoor temperatures Tj Declared coefficient of performance or gas utili...

Страница 28: ...www mundoclima com C N POLES 249 P1 08013 BARCELONA SPAIN 34 93 446 27 80...