background image

1.    IMPORTANT SAFETY INFORMATION

To  prevent  injury  to  the  user  or  other  people  and  property 
damage, the following  instructions must be followed. Incorrect 
operation  due  to  ignoring  of  instructions  may  cause  harm  or 
damage. 

WARNING

Do not insert fingers, rods or other objects into the air 
inlet or outlet.

 

When the fan is rotating at high speed, it will cause injury. 

Never use a flammable spray such as hair spray, 
lacqueror paint near the unit.

 

It may cause a fire. 

Never touch the air outlet or the horizontal blades while 
the swing flap is in operation. 

Fingers may become caught or the unit may break down. 

Never put any objects into the air inlet or outlet.

 

Objects touching the fan at high speed can be dangerous.

Never inspect or service the unit by yourself.

 

Ask a qualified service person to perform this work. 

Do not dispose this product as unsorted 
municipal waste. Collection of such waste
 separately for special treatment is necessary.

Do not dispose of electrical appliances as unsorted 
municipal waste, use separate collection facilities.

CAUTION

Contact  you  local  government  for  information  regarding  the 
connection systems available.

If  electrical  appliances  are  disposed  of  in  landfills  or 
dumps,  hazardous  substances  can  leak  into  the 
groundeater  and  get  into  the  food  chain,  damaging  your 
health and well-being.

To prevent refrigerant leak, contact your dealer. 

When  the  system  is  installed  and  runs  in  a  small  room,  it  is 
required to keep the concentration of the refrigerant, if by any 
chance coming out, below the limit. Otherwise, oxygen in the 
room may be affected, resulting in a serious accident. 

The refrigerant in the air conditioner is safe and normally 
does not leak. 

If  the  refrigerant  leaks  in  the  room,  contact  with  a  fire  of  a 
burner, a heater or a cooker may result in a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the 
room,  and  contact  the  dealer  where  you  purchased  the 
unit. 

Do not use the air conditioner until a service person confirms 
that the portion where the refrigerant leaks is repaired. 

If the supply cord is damaged,it must be replaced by the 
manufacturer,its  service  angent  or  similarly  qualified 
person in order to avoid a hazard. 

WARNING

CAUTION

 

Failure to observe a caution may result in injury or damage
to the equipment.

Failure to observe a warning may result in death. The 
appliance shall be installed in accordance with national 
wiring regulations.

Do not use the air conditioner for other purposes. 

In order to avoid any quality deterioration, do not use the unit 
for cooling precision instruments, food, plants, animals or 
works of art. 

Before cleaning, be sure to stop the operation, turn the 
breaker off or pull out the supply cord. 

Otherwise, an electric shock and injury may result. 

In order to avoid electric shock or fire, make sure that an 
earth leak detector is installed.

Be sure the air conditioner is grounded.

 

In order to avoid electric shock, make sure that the unit is 
grounded and that the earth wire is not connected to gas or 
water pipe, lightning conductor or telephone earth wire.

In order to avoid injury, do not remove the fan guard of 
the outdoor unit.

Ask your dealer for installation of the air conditioner. 

Incomplete installation performed by yourself may result in a 
water leakage, electric shock, and fire. 

Ask your dealer for improvement, repair, and 
maintenance.

 

Incomplete improvement, repair, and maintenance may result 
in a water leakage, electric shock, and fire. 

In order to avoid electric shock, fire or injury, or if you 
detect any abnormality such as smell of fire, turn off the 
power supply and call your dealer for instructions.

Never let the indoor unit or the remote controller get wet.

 

It may cause an electric shock or a fire.

Never press the button of the remote controller with a 
hard, pointed object.

 

The remote controller may be damaged. 

Never replace a fuse with that of wrong rated current or 
other wires when a fuse blows out. 

Use of wire or copper wire may cause the unit to break down 
or cause a fire. 

It is not good for your health to expose your body to the 
air flow for a long time.

where  oil  gas,salty  air(near  the  coast),caustic  gas(the 
sulfide  in  hotspring)  exist,  otherwise  it  may  damage  the 
unit  and  shorten  the  life  span  of  the  manchine.If  the 
situations above can't be avoided, choose a anticorrosive 
model.

The safty precautions listed here are divided into two categories. In 
either case, important safty information is listed which must be read 
carefully.

CONTENTS

PAGE

IMPORTANT  SAFETY  INFORMATION......................................................16

OPERATION  RANGE................................................................................17

OPERATION  AND  PERFORMANCE..........................................................17

MALFUNCTION  CODE  OF  OUTDOOR  UNIT      ...........................................1

FOLLOWING  SYMPTOMS  ARE  NOT  AIR  CONDITIONER  TROUBLES........20

TROUBLESHOOTING...............................................................................20

MAINTENANCE  AND  PEPAIR................................................

...................22

OWNER'S MANUAL

Owner's manual

9

0

0

16

Mini MVD V6M

Содержание MINI MVD V6M

Страница 1: ...English MVD www mundoclima com Installation and owner s manual MINI MVD V6M OUTDOOR UNIT and information requirements CL23274 to CL23275 MVD V280W DGN1 MVD V335W DGN1...

Страница 2: ...d use This unit must be installed by a professional according RD 795 2010 RD 1027 2007 and RD 238 2013 The power supply must be SINGLE PHASE one phase L and one neutral N with his grounded power GND s...

Страница 3: ...ly if there are possible damage Do not install in a place that might increase the vibration of the unit To avoid personal injury with sharp edges be careful when handling parts Perform installation wo...

Страница 4: ...of the conventional refrigerant take out the flare nut attached to the main unit of the air conditioner and use it Before installation Be careful to the following items before installation Air purge...

Страница 5: ...or unit power cord and connecting wire at least 1m away from TV set or radio to prevent noise or picture interference Strong wind Strong wind 3 2 Installation space Unit mm 300 600 300 0 0 0 3 Wall or...

Страница 6: ...the frozen condensed water will block up the water outlet please pull out the rubber stopper of the reserve water outlet If that still fails to satisfy for the water draining please knock open the ot...

Страница 7: ...connected to the indoor unit is at least 0 5m 4 4 Connecting method main pipe The branch pipes of indoor unit The pipe after the first branch do not drect connect with the indoor unit The pipe after...

Страница 8: ...g nut 15 9 Flaring nut 6 4 Flaring nut Wall mounted 56 15 9 Flaring nut 9 5 Flaring nut 6 4 Flaring nut 9 5 Flaring nut 9 5 Flaring nut One sided air outlet 18 45 12 7 Flaring nut 6 4 Flaring nut One...

Страница 9: ...e gas side main pipe size Inner branch pipes are a f the size selection please refers to Table4 6 Note The max length of the branch pipe should not longer than 15m Indoor unit branch pipe The main pip...

Страница 10: ...t to be Added Using vacuum pump to do the vacuum never using refrigerant to expel the air Vacuuming should be done from both liquid side and gas side simultaneously Calculate the added refrigerant acc...

Страница 11: ...rol system connection of the outdoor unit P Q E L N P Q E L N P Q E L N P Q E L N L2 L3 N L1 K2 E O K1 A E Y E P X Q E Power supply for the outdoor unit monitor Outdoor unit Reserved Optional L N K1 K...

Страница 12: ...he signal cable insert electric wires in their respective electric wire pipes and reserve a proper inter wire distance distance between power cables lower than 10 A 300 mm lower than 50 A 500 mm Use a...

Страница 13: ...NOTE Single phase indoor unit Wire controller The reserved wire control function is indicated in broken line table users can purchase the wire controller when necessary in broken line table users can...

Страница 14: ...tilator A Ventilation peristome Leak hunting siren should be installed in places easily keep refrigerant Indoor unit Outdoor unit Indoor unit Room full of leak refrigerant All refrigerant has run up F...

Страница 15: ...ween main board and compressor drive board Inverter module protection Qty of indoor units mismatching High pressure sensor error M HOME for the indoor and outdoor units does not match Phase sequence e...

Страница 16: ...equipment Failure to observe a warning may result in death The appliance shall be installed in accordance with national wiring regulations Do not use the air conditioner for other purposes In order to...

Страница 17: ...t supervision When capacity of indoor unit greater than the sum of 100 capacity of indoor unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in order to ensur...

Страница 18: ...starts immediately after operation The indoor unit of the intelligent inverter centralized air conditioner can be controlled solely but the indoor unit in the same system can not run cooling and heati...

Страница 19: ...ble Irrecoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable P8 F1 E1 High pressure protection M HOME for the indoor and outdoor units does not match Display F...

Страница 20: ...d when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after h...

Страница 21: ...indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is to...

Страница 22: ...r goes off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatically start and...

Страница 23: ...3 6 4 2 6 732C 3 2C 87 5 3 6 37 3 37 62 and hydrogen sulphide G F7 2 88 8 7 62 26 5 26 63 2 5 E6 3 where the air conditioning is on for 24 hours a day As the use of the unit for many years will eventu...

Страница 24: ...oad at given outdoor temperatures Tj Prated c Pdc Pdc Pdc Pdc Cdc 0 25 33 5 kW Seasonal space cooling energy efficiency s c 199 8 Symbol Value Unit Off mode Thermosat off mode Crankcase heater mode St...

Страница 25: ...d heating capacity Degradation co efficient for heat pumps Declared heating capacity for part load at indoor teperature 20 and outdoor temperatures Tj Declared coefficient of performance or gas utilis...

Страница 26: ...y factor for part load at given outdoor temperatures Tj Prated c Pdc Pdc Pdc Pdc Cdc 0 25 28 0 kW Seasonal space cooling energy efficiency s c 201 0 Symbol Value Unit Off mode Thermosat off mode Crank...

Страница 27: ...ed heating capacity Degradation co efficient for heat pumps Declared heating capacity for part load at indoor teperature 20 and outdoor temperatures Tj Declared coefficient of performance or gas utili...

Страница 28: ...www mundoclima com C N POLES 249 P1 08013 BARCELONA SPAIN 34 93 446 27 80...

Отзывы: