INDOOR UNIT INSTALLATION
2. Indoor unit installation
5
1) Fit the installation plate horizontally on structural parts of the wall with spaces
arround the installation plate.
2) If the wall is made of brick, concrete or like, drill five or eight 5mm diameter holes
in the wall. Insert Clip anchor for appropiates mounting screws.
1. Determine hole positions according to left and right
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with
φ
65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal
grid, metal plate or the like.
Wall
Indoor
Outdoor
5-7mm
Fit the installation plate
Drill a hole in the w all
Agujero lado
izquierdo 65 mm
Agujero lado derecho
65 mm
Dimensiones
unidad interior
717 mm
63 mm
302 mm
27 mm
11mm(0.43in)
63 mm
237 mm
412 mm
107 mm
137 mm
117 mm
39 mm
128 mm
Agujero lado
derecho 65mm
964 mm
262 mm
481.6 mm
256.6 mm
44 mm
256.6 mm
111 mm
262.2 mm
29.2 mm
325 mm
48 mm
48 mm
Agujero lado
izquierdo 65 mm
Agujero lado
derecho
65 mm
Dimensiones
unidad interior
805 mm
302 mm
27 mm
53 mm
224.6 mm
427.9 mm
128 mm
112 mm
113 mm
39 mm
163 mm
Agujero
lado derecho 65 mm
1106 mm
598.4 mm
319.5 mm
227.8 mm
53.7 mm
227.8 mm
319.5 mm
189.4 mm
342 mm
45 mm
45 mm
MUPR-12-H6M
MUPR-09-H6M
MUPR-18-H6M
MUPR-24-H6M
53 mm
Dimensiones
unidad interior
Dimensiones
unidad interior
Agujero lado
izquierdo 65 mm
Agujero lado
izquierdo 65 mm