2.    INSTALLATION INFORMATION 

Ground the air conditioner.

 

Do not connect the ground wire to gas or water pipes, 
lightning rod or a telephone ground wire.Incomplete 
grounding may result in electric shocks. 
 

Be sure to install an earth leakage breaker.

 

Failure to install an earth leakage breaker may result in 
electric shocks. 

 

Connect the outdoor unit wires , then connect the indoor 
unit wires.

  

You are not allow to connect the air conditioner with the 
power source until wiring and piping the air conditioner is 
done. 

 
While following the instructions in this installation 
manual, install drain piping in order to ensure proper 
drainage and insulate piping in order to prevent 
condensation.

 

Improper drain piping may result in water leakage and 
property damage. 
 

Install the indoor and outdoor units, power supply wiring 
and connecting wires at least 1 meter away from 
televisions or radios in order to prevent image 
interference or noise. 

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise. 

 
The appliance is not intended for use by young children 
or inferm persons without supervision.

 

 

Don't install the air conditioner in the following locations: 

There is petrolatum existing. 
 
There is salty air surrounding (near the coast). 
 
There is caustic gas (the sulfide, for example) existing  
in the air (near a hot spring). 
 
The Volt vibrates violently (in the factories). 
 
In buses or cabinets. 
 
In kitchen where it is full of oil gas. 
 
There is strong electromagnetic wave existing. 
 
There are inflammable materials or gas. 
 
There is acid or alkaline liquid evaporating. 
 
Other special conditions. 
 
The appliance shall not be installed in the laundry. 
 

If the refrigerant leaks during installation, ventilate the 
area immediately. 

Toxic gas may be produced if the refrigerant comes into the 
place contacting with fire. 
 

The temperature of refrigerant circuit will be high, please 
keep the interconnection cable away from the copper 
tube. 
 
After completing the installation work, check that the 
refrigerant does not leak. 

Toxic gas may be produced if the refrigerant leaks into the 
room and comes into contact with a source of fire, such as a 
fan heater, stove or cooker. 

INSTALLATION ORDER 

Select the location; 
 
Install the indoor unit; 
 
Install the outdoor unit; 
 
Install the connecting pipe ; 
 
Connect the drain pipe; 
 
Wiring; 
 
Test operation. 

CAUTION 

3.    ATTACHED FITTINGS 

Please check whether the following fittings are of full scope.  
If there are some spare fittings , please restore them carefully.  

  Name of  
Accessories 

Installation manual 

Hook 

Hanging arm 

Network matching wire 

Drainage pipe 

Qty  

(This manual) 

Usage 

Outline 

1. Remote controller.....................................1 

2. Remote controller holder..........................1 

3. Mounting screw  (ST2.9x10-C-H)..............2 

4. Alkaline dry battery(AM4) 

   .........................2 

Remote controller & Its Frame 

 

 

The indoor unit which at the  

terminal of communication s- 

ystem should connect a  im- 

pedance between port P an- 

d port Q. 

Drainage 

Installation manual

2

Ceiling Floor

Содержание CL23400

Страница 1: ...Ceiling Floor MVD DC Installation manual MVD English CL23400 to CL23407 www mundoclima com...

Страница 2: ...and fire Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The app...

Страница 3: ...by young children or inferm persons without supervision Don t install the air conditioner in the following locations There is petrolatum existing There is salty air surrounding near the coast There i...

Страница 4: ...oint of refrigerant pipe J Liquid side Drain point Fig 4 1 Fig 4 2 Fig 4 3 Fig 4 4 WOODEN CONSTRUCTION NEW CONCRETE BRICKS FOR ORIGINAL CONCRETE BRICKS Steel bar Embedding screw bolt Pipe hanging and...

Страница 5: ...lt Refer to Fig 4 11 Prepare the mounting bolts on the unit Refer to Fig 4 12 Screw nut Washer Hanging screw bolt Hanging arm Fig 4 11 20 25mm Fig 4 6 Fig 4 7 1 Fix the hook with tapping screw onto th...

Страница 6: ...ble 4 2 4 5 Material and size of the piping 5 1 The Procedure of Connecting Pipes 5 1 1 Measure the necessary length of the connecting pipe and make it by the following way 1 Connect the indoor unit a...

Страница 7: ...ge by checking it with leak detector or soap water 6 Cover the joint of the connecting pipe to the indoor unit with the soundproof insulating sheath fittings and bind it well with the tapes to prevent...

Страница 8: ...es 8 Connect the indoor unit to power only after the refrigerant has been vacuumed 9 Don t connect the power wire to the signal wire connection end 7 1 The specification of power Table 7 1 MODEL W 220...

Страница 9: ...8 Ceiling Floor Note To make the addressing you can contact with Mundoclima after sales service If the outdoor unit has Auto address function is not necessary to set manually the indoor unit address I...

Страница 10: ...tdoor unit DC FAN error 1 2 3 4 5 7 6 No address when first time power on Defrost LED flash or show E0 Timer LED flash or show E1 Run LED flash or show E2 Run LED flash or show E3 Run LED flash or sho...

Страница 11: ...mode 0 means add auto searching mode default setting 1 means DC fan Is chosen 0 means AC fan Is chosen Reserved 1234 SW1 ON 1234 SW1 ON 1234 SW1 ON 1234 SW1 ON 1234 SW1 ON 1234 SW1 ON SW1 definition 0...

Страница 12: ...et the air conditioner under the mode of COOLING with the remote controller and check the following points If there is any malfunction please resolve it according to the chapter Troubleshooting in the...

Страница 13: ...Installation manual NOTES 12 Ceiling Floor...

Страница 14: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com MVD...

Отзывы: