background image

 

 

1.    IMPORTANT SAFETY INFORMATION 

To  prevent  injury  to  the  user  or  other  people  and  property 
damage, the following  instructions must be followed. Incorrect 
operation  due  to  ignoring  of  instructions  may  cause  harm  or 
damage.  

Ask your dealer for installation of the air conditioner. 

 

Incomplete  installation  performed  by  yourself  may  result  in  a 
water leakage, electric shock, and fire.  
 

Ask your dealer for improvement, repair, and 
maintenance.

  

Incomplete  improvement,  repair,  and  maintenance  may  result 
in a water leakage, electric shock, and fire.  
 

In  order  to  avoid  electric  shock,  fire  or  injury,  or  if  you 
detect  any  abnormality  such  as  smell  of  fire,  turn  off  the 
power supply and call your dealer for instructions. 

 

Never let the indoor unit or the remote controller get wet.

  

It may cause an electric shock or a fire. 
 

Never  press  the  button  of  the  remote  controller  with  a 
hard, pointed object.

  

The remote controller may be damaged.  
 

Never  replace  a  fuse  with  that  of  wrong  rated  current  or 
other wires when a fuse blows out. 

 

Use of wire or copper wire may cause the unit to break down 
or cause a fire. 

 

Do not use the air conditioner for other purposes. 

 

In order to avoid any quality deterioration, do not use the unit 
for  cooling  precision  instruments,  food,  plants,  animals  or 
works of art.  
 

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the 
breaker off or pull out the supply cord. 

 

Otherwise, an electric shock and injury may result. 
 

In order to avoid electric shock or fire, make sure that an 
earth leak detector is installed.

 

 

Be sure the air conditioner is grounded.

  

In  order  to  avoid  electric  shock,  make  sure  that  the  unit  is 
grounded  and  that  the  earth  wire  is  not  connected  to  gas  or 
water pipe, lightning conductor or telephone earth wire.  

It is not good for your health to expose your body to the 
air flow for a long time.

 

 

Do  not  insert  fingers,  rods  or  other  objects  into  the  air 
inlet or outlet.

  

When the fan is rotating at high speed, it will cause injury.  

 

Never use a flammable spray such as hair spray,lacquer 
or paint near the unit.

  

It may cause a fire.  
 

Never  touch  the  air  outlet  or  the  horizontal  blades  while 
the swing flap is in operation. 

 

Fingers may become caught or the unit may break down.  
 

Never put any objects into the air inlet or outlet.

  

Objects touching the fan at high speed can be dangerous. 
 

Never inspect or service the unit by yourself.

  

Ask a qualified service person to perform this work.  
 

Do  not  dispose  this  product  as  unsorted  municipal 
waste.Collection  of  such  waste  separately  for  special 
treatment is necessary. 

 
Do not dispose of electrical appliances as unsorted municipal 
waste, use separate collection facilities. 
Contact  you  local  government  for  information  regarding  the 
connection systems available. 

 
If  electrical  appliances  are  disposed  of  in  landfills  or 
dumps,  hazardous  substances  can  leak  into  the 
groundeater  and  get  into  the  food  chain,  damaging  your 
health and well-being 
 
To prevent refrigerant leak, contact your dealer. 

 

When  the  system  is  installed  and  runs  in  a  small  room,  it  is 
required to keep the concentration of the refrigerant, if by any 
chance coming out, below the limit. Otherwise, oxygen in the 
room may be affected, resulting in a serious accident.  
 

The refrigerant in the air conditioner is safe and normally 
does not leak.  

If  the  refrigerant  leaks  in  the  room,  contact  with  a  fire  of  a 
burner, a heater or a cooker may result in a harmful gas. 
 

Turn  off  any  combustible  heating  devices,  ventilate  the 
room,  and  contact  the  dealer  where  you  purchased  the 
unit. 

 

Do not use the air conditioner until a service person confirms 
that the portion where the refrigerant leaks is repaired. 

The   safty   precautions   listed   here   are   divided   into   two   categories.   In  
either   case,   important   safty   information   is   listed   which   must   be   read  
carefull y . 

Failure   to   observe   a   caution   may   result   in   injury   or   damage   
to   the   equipment. 

in death. 

  

 

The appliance shall be installed in accordance with national 
 wiring regulations.

Failure to observe a warning may result 

 

CONTENTS 

PAGE 

 

IMPORTANT SAFETY INFORMATION.......................................................9

PARTS NAMES........................................................................................ 

AIR CONDITIONER OPERATIONS AND PERFORMANCE........................... 

HINTS FOR ECONOMICAL OPERATION....................................................

MAINTENANCE.......................................................................................

FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES........ 

TROUBLESHOOTING............................................................................... 

 

CAUTION 

CAUTION 

WARNING 

WARNING 

20

21

22

22

23

24

25

ADJUSTING AIR FLOW DIRECTION ..........................................................

22

OWNER'S MANUAL

20

Содержание CL20241

Страница 1: ...nd English owner s manual MUSTR H6 CEILING FLOOR SERIE H6 www mundoclima com Thank you very muchfor purchasing our products Please read this manual carefully before installing and using the unit CL202...

Страница 2: ...RD 795 2010 RD 1027 2007 and RD 238 2013 The power supply must be SINGLE PHASE one phase L and one neutral N with his grounded power GND switch Any breach of these specifications involve a breach of...

Страница 3: ...to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find manyanswer...

Страница 4: ...k and fire Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The ap...

Страница 5: ...distance of 1 meter may not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditioner...

Страница 6: ...Binding tape 3 Seal sponge 4 Drain joint 5 Seal ring 6 Remote controller RG57 7 Frame 8 Mounting screw ST2 9 0 C H 9 Alkaline dry batteries Am4 10 Magnetic ring twist the electirc wires L and N around...

Страница 7: ...fferent from the air conditioner you purchased depend on model The actual shape shall prevail NOTE 35mm 1000mm 35mm 35mm B C D A E Hook Connecting point of refrigerant pipe Connecting point of refrige...

Страница 8: ...beam Roof beam Ceiling Hanging screw bolts Blade shape insertion Slide insertion Steel bar Embedding screw bolt Pipe hanging andembedding screw bolt Install the hanging hook with expansible bolt into...

Страница 9: ...l areas or other places with salty atmosphere of sulfate gas corrosion may shorten the life of the air conditioner 9 Since drain flows out of the outdoor unit do not place under the unit anything whic...

Страница 10: ...s the wall height on the outlet side should be 1200mm or less s 1 Installing outdoor unit 2 Drain work If drain work is necessary follow the procedures below Use drain plug for drainage If the drain p...

Страница 11: ...ecautions 3 1 Flaring the pipe end 1 Cut the pipe end with a pipe cutter 2 Remove burrs with the cut surface facing downward so that the chips do not enter the pipe 5 Check that the flaring is properl...

Страница 12: ...is complete wipe all soapy water off 7 Disconnect charging hose from gas stop valve s service port then fully open liquid and gas stop valves Do not attempt to turn valve rod byond its stop 8 Tighten...

Страница 13: ...Gas pipe 4 CONNECT THE DRAIN PIPE INSTALLATION MANUAL Keep piping as short as possible and slope it downwards at a gradient of at least 1 100 so that air may not remain trapped inside the pipe Keep p...

Страница 14: ...The specification of power Minimum norminal cross sectional area of conductors Rated current of appliance A Nominal cross sectional area mm2 6 0 75 6 and 10 1 0 10 and 16 1 5 16 and 25 2 5 25 and 32...

Страница 15: ...B To use the signal ON OFF you should cut away the jumper CN23 The operation is as follows With the unit running if the contact CN23 opens unit stops and remote control is locked CP shown in the displ...

Страница 16: ...sult in overheating and in the worst case electric shock or fire 2 3 Cover Bolts control box lid to wire the outdoor unit indoor unit and the remote controller Note Control and settings For more infor...

Страница 17: ...ide stop valve Electrify crank case heater for 6 hours Set to cooling operation with the remote controller and start operation by pushing ON OFF button Turn off the main power supply after operation C...

Страница 18: ...use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find manyanswers t...

Страница 19: ...MANUAL INDOOR UNIT OUTDOOR UNIT 1 2 5 4 7 6 8 8 9 RESE T TIM E ON TIM E OFF CLO CK SW ING AIR DIRE CTIO N OK ECO SW ING MO DE FAN SPE ED M LOCK C H AU TO CO OL DR Y HE AT FAN TEM P SE T CLOC K SET HO...

Страница 20: ...ire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the unit may break down Never put any objects into the air inlet or outlet Obj...

Страница 21: ...install the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out The appliance is not intended for use by young...

Страница 22: ...ary Set the timer for the desired operating time Never put obstructions near the air outlet or the air inlet Or it will cause lower efficiency even a sudden stop Adjust the air flow direction properly...

Страница 23: ...of indoor units and outdoor units Clean air filters and casings of indoor units Refer to Cleaning the air filter for details on how to proceed and make sure to install cleaned air filters back in the...

Страница 24: ...irst time in a long time This is because dust has gotten into the unit The unit can absorb the smell of rooms furniture cigarettes etc and then emit it again Symptom 7 The outdoor unit fan does not sp...

Страница 25: ...malfunction 4 E4 OFF 5 Indoor room temperature sensor T1 open circuit or short circuit 5 E5 OFF 6 Indoor coil temperature sensor T2 open circuit or short circuit 6 EC OFF 7 Regfrigerante leakage detec...

Страница 26: ...circuit is blocked Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the controller Set the temperature properly Wait Check leakage and rightly recharge...

Страница 27: ...ler to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation h...

Страница 28: ...REMOTE CONTROLLER Please read this manual carefully before installing and using the unit 28...

Страница 29: ...l All the functions described are accomplished by the unit If the unit has no this feature there is no corresponding operation happened when press the relative button on the remote controller When the...

Страница 30: ...h this button to decrease the indoor o o temperature setting in 1 C increments to 17 C DOWN Button 6 8 9 7 Press this button to initiate the auto on time sequence Each press will increase the auto tim...

Страница 31: ...or time under TIMER setting AUTO HEAT FAN COOL DRY How to use the buttons Auto operation Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the indoor...

Страница 32: ...on to select DRY mode 2 Press the UP DOWN buttons to set the desired temperature 3 Press the ON OFF button to start the air conditioner The temperature O O can be set within a range of 17 C 30 C O in...

Страница 33: ...After setting the TIMER OFF there will be a one second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disap...

Страница 34: ...ON display 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON OFF indicator remains on and this function is activated TIMER OFF TIMER ON On Stop Start oper...

Страница 35: ...rom falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer Do not drop the remote controller Handle with care D...

Страница 36: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...

Отзывы: