Tech support may ask you to provide this information. As shown in the above figure, the sensors values are for the
engineers to check whether any sensor has a malfunction. If you meet any problem about use, please take a photo
of this page and contact us.
Figure 6-4 Sensor Values
Figure 6-5 CIS Calibration Steps
6.1.1. Read Sensor Values
6.1.2. CIS Calibration
If you have problems with banknote detection errors, please try to calibrate the CIS. The CIS calibration
steps are shown in Figure 5-5. For more detail instruction, we recommend you to review the reference manual
or watch the following video:
https://bit.ly/2C17fom
The contact image sensor (CIS) of the machine has been calibrated properly from the factory. With regular,
use, the sensor’s sensitivity decreases which can lead to image errors. To resolve the issue, the IMC08 can
be re-calibrated using the white calibration paper that came with the machine.
Figure 6-3 Service Menu