Gearbox adjustment
The linear actuator for the
adjusting of fertiliser target rate is
at 0 and not moving. The fertiliser
calibration has failed and is outside
the T-value limits.
On the Settings screen, select
3. Factory Setup
→
enter the PIN code 1234
→
select 2. Actuator Setup
→
select CUR as your Line
Type setting
→
select Curve Factors
→
set the T-value manually.
If only “########” is shown on
the line, go to the line by
pressing OK. First enter
“000000” as the value and then
accept it by pressing the OK
button. The value “0.00000”
should now appear on the line.
Repeat the above and enter
“0.40000” as the value.
The middle markers do not work
automatically or in the manual
position.
A new value has been entered for
the fertiliser rate and the linear
actuator has not reached the
target.
On models with a roller
adjustment, the seed shaft has to
rotate in order for the linear
actuator to move.
Check the function of the
adjusting of fertiliser target
rate according to
section 7.1.14. Checking the
functioning of the adjusting of
Operation and maintenance manual
FX300 and FX400 Comfort
1.00
176 (189)
Содержание FX300 Comfort
Страница 181: ...Hydraulic schematics FX300 and FX400 1 Hydraulic schematics FX300...
Страница 182: ...Hydraulic schematics FX300 and FX400 2...
Страница 183: ...Hydraulic schematics FX300 and FX400 3 Hydraulic schematics FX400...
Страница 184: ...Hydraulic schematics FX300 and FX400 4...
Страница 185: ...Electrical schematics FX300 and FX400 Comfort 1 Electrical schematics...
Страница 186: ...Electrical schematics FX300 and FX400 Comfort 2...
Страница 187: ...Electrical schematics FX300 and FX400 Comfort 3...