![Multiva Cerex 300 Comfort Скачать руководство пользователя страница 176](http://html1.mh-extra.com/html/multiva/cerex-300-comfort/cerex-300-comfort_operation-and-maintenance-manual_1856359176.webp)
The machine cannot
be lifted
1. The lift
inhibit function
is enabled
1. Disable the lift inhibit function in accordance
with section 6.3.1. Active operating mode.
2. Machine
lifting circuit
ball valve is
closed
2. Open the machine lifting circuit ball valve in
accordance with section 5.3.5. Using the machine
3. The quick
coupling is
open
3. Check the connection of the quick-release
coupling.
The machine cannot
be lowered
1. Machine
lifting circuit
ball valve is
closed
1. Open the machine lifting circuit ball valve in
accordance with section 5.3.5. Using the machine
2. The quick
coupling is
open
2. Check the connection of the quick-release
coupling.
3. The stoppers
are in place in
the lifting
cylinder
3. Remove the stoppers from the lifting cylinder.
Hopper alarm does
not function
1. The alarm
has been
disabled
1. Enable the alarm from the settings in accordance
with section 4.2.4.1. User setup.
The axle rotation
guard does not
function
1. The alarm
has been
disabled
1. Enable the alarm from the settings in accordance
with section 4.2.4.1. User setup.
Operation and maintenance manual
Cerex 300 and Cerex 400 Comfort
1.00
176 (187)
Содержание Cerex 300 Comfort
Страница 179: ...Hydraulic schematics Cerex 300 and Cerex 400 1 Hydraulic schematics Cerex 300...
Страница 180: ...Hydraulic schematics Cerex 300 and Cerex 400 2...
Страница 181: ...Hydraulic schematics Cerex 300 and Cerex 400 3 Hydraulic schematics Cerex 400...
Страница 182: ...Hydraulic schematics Cerex 300 and Cerex 400 4...
Страница 183: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 1 Electrical schematics...
Страница 184: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 2...
Страница 185: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 3...