Chapter 4 - V.22bis Commands
Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide
36
Summary of S-Parameter Defaults
Register
Function
Range/Units
Default*
S0
Rings to Auto-Answer
0-255 rings
0
S1
Ring Counter
0-255 rings
0
S2
Escape Character
0-255 ASCII
43
S3
Carriage Return Character
0-127 ASCII
13
S4
Line Feed Character
0-127 ASCII
10
S5
Backspace Character
0-255 ASCII
8
S6
Wait Time before Blind Dialing or for Dial Tone
2-255 s
2
S7
Wait Time for Carrier, Silence, or Dial Tone
1-255 s
50
S8
Pause Time for Dial Delay Modifier
2-255 s
2
S9
Carrier Detect Response Time
1-255 0.1 s
6
S10
Lost Carrier To Hang Up Delay
1-255 0.1 s
14
S11
DTMF Tone Duration
50-255 0.001 s
85
S12
Escape Prompt Delay (EPD)
0-255 0.02 s
50
S14
General Bit Mapped Options Status
138 (8Ah)
S16
Test Mode Bit Mapped Options Status
0
S19
Reserved
0
S20
Reserved
0
S21
V.24/General Bit Mapped Options Status
52 (34h)
S22
Speaker/Results Bit Mapped Options Status
117 (75h)
S23
General Bit Mapped Options Status
0
S24
Sleep Inactivity Timer
0-255 s
0
S25
Delay to DTR Off
0-255 s or 0.01 s
5
S26
RTS-to-CTS Delay
0-255 0.01 s
1
S27
General Bit Mapped Options Status
73 (49h)
S28
General Bit-Mapped Options Status
0
S29
Flash Dial Modifier Time
0-255 10 ms
70
S30
Disconnect Inactivity Timer
0-255 10 s
0
S31
General Bit-Mapped Options Status
192 (C0h)
S36
LAPM Failure Control
7
S38
Delay Before Forced Hangup
0-255 s
20
S39
Flow Control Bit Mapped Options Status
3
S40
General Bit-Mapped Options Status
104 (68h)
S41
General Bit-Mapped Options Status
195 (C3h)
S86
Call Failure Indication
0-26
21
S91
PSTN Transmit Attenuation Level
0-15 dBm
10 (Country
dependent)
S95
Extended Result Codes Control
0
* Default values may be modified using patch code.